Read Sharp MX-6240N / MX-7040N (serv.man30) Service Manual online
MX-7040N VARIOUS STORAGE DATA HANDLING 11 – 7
C. Procedures necessary for SD card replacement
(1)
SD card data and backup
Some SD card storage data can be backed up, and some other cannot. Some SD card storage data can be reinstalled, and some other cannot.
If the SD card operates normally before replacement and data can be backed up, back up the data before replacement of the SD card referring
to the storage data list. Then reinstall the data after replacement of the SD card.
to the storage data list. Then reinstall the data after replacement of the SD card.
The SD card includes the following data.
SD card backup
1)
When there are some FAX/Internet Fax data received, use
SIM66-62 to backup the image data to the USB memory in the
PDF file type, and give the PDF file to the user. (The data can-
not be restored to the machine.)
SIM66-62 to backup the image data to the USB memory in the
PDF file type, and give the PDF file to the user. (The data can-
not be restored to the machine.)
2)
Replace the SD card with a new one.
3)
Upgrade the firmware to the latest version.
4)
Use SIM66-10 to clear the image send memory. (Ensure con-
sistency between the HDD data and the image-related mem-
ory,)
sistency between the HDD data and the image-related mem-
ory,)
CAUTION: When replacing the SD card, be sure to use only the
specified SD card supplied as a service part.
The firmware required for booting must be included
in the SD card used in this machine. The commer-
cially available SD cards have no such data.
in the SD card used in this machine. The commer-
cially available SD cards have no such data.
NOTE: When E7-07 error occurs, there may be some trouble in
the SD card.
D. Procedures necessary for CF card replacement
(1)
CF card data and backup
Some CF card storage data can be backed up, and some other cannot. Some CF card storage data can be reinstalled, and some other cannot.
If the CF card operates normally before replacement and data can be backed up, back up the data before replacement of the CF card referring
to the storage data list. Then reinstall the data after replacement of the CF card.
to the storage data list. Then reinstall the data after replacement of the CF card.
The CF card includes the following data.
CF card backup
1)
Use SIM56-02 to backup the CF card data to the USB mem-
ory.
ory.
2)
When the operation panel home screen has been customized,
backup the CF card data by using the device cloning function.
backup the CF card data by using the device cloning function.
3)
Replace the CF card with a new one.
4)
Upgrade the firmware to the latest version.
5)
Use SIM56-02 to restore the data backed up in procedure 1).
6)
Restore the data backed up in procedure 2) by using the
device cloning function.
device cloning function.
CAUTION: When replacing the CF card, be sure to use only the
specified CF card supplied as a service part.
The firmware required for booting must be included
in the CF card used in this machine. The commer-
cially available CF cards have no such data.
in the CF card used in this machine. The commer-
cially available CF cards have no such data.
NOTE: When E7-A6 error occurs, there may be some trouble in
the CF card.
Partition
number
Stored data
Enable/Disable of
data backup
Backup means
Enable/Disable
of data reinstall
Data reinstall
procedures
L-201
ICU firmware
(Reus section)
(Reus section)
ICU firmware
(Including the OS section)
(Including the OS section)
Disable
Enable
SIM49-1
I-201
FAX reception data
(Backup)
(Backup)
FAX/Internet Fax reception image
data
data
Enable
SIM66-62
Disable
Partition
number
Stored data
Enable/Disable of
data backup
Backup means
Enable/Disable
of data reinstall
Data reinstall
procedures
L-101
ICU firmware
ICU firmware
(Including the OS section)
(Including the OS section)
Disable
Enable
SIM49-1
S-101
ICU firmware fixed data
font
web help
spdl
UI content file
lang (message data)
graph (graphic data)
eOSA Delegator
Standard color profile
Option FontROM
web help
spdl
UI content file
lang (message data)
graph (graphic data)
eOSA Delegator
Standard color profile
Option FontROM
Disable
Enable
SIM49-1
S-102
System data
Setting value data file (System
setting/SIM setting data (Image
quality adjustment)/FAX Soft SW)
setting/SIM setting data (Image
quality adjustment)/FAX Soft SW)
Enable
SIM56-02
Enable
SIM56-02