Read Sharp MX-6201N / MX-7001N (serv.man43) Service Manual online
MX-7001N FAN, FILTER SECTION S – 7
6)
Close the control box (K).
7)
Remove the screw (L), and push the part (M), disengage the
pawl (N). Disengage the pawl (O), and remove the inner venti-
lation fan motor (Right) unit (P).
pawl (N). Disengage the pawl (O), and remove the inner venti-
lation fan motor (Right) unit (P).
8)
Remove the screws (Q), and remove the inner ventilation fan
motor (Right) (R).
motor (Right) (R).
(9) BK process cooling fan motor
1)
Remove the rear cabinet and the rear cabinet lower. (Refer to
the "[A] EXTERNAL OUTFIT".)
the "[A] EXTERNAL OUTFIT".)
2)
Remove the screw (A), and open the control box (B).
3)
Disconnect the connector (C), and remove the snap band (D).
Remove the screw (E).and remove the BK process cooling fan
motor unit (F).
Remove the screw (E).and remove the BK process cooling fan
motor unit (F).
K
M
L
N
P
O
R
Q
i
Parts
k
BK process cooling fan motor
k
B
B
A
A
C
D
E
F