Read Sharp MX-6201N / MX-7001N (serv.man20) Service Manual online
MX-7001N SELF DIAG AND TROUBLE CODE 8 – 17
F1-60
Communication trouble between the
finisher and the inserter
finisher and the inserter
F1-61
Inserter EEPROM trouble
F1-62
Inserter reverse sensor trouble
F2-02
Toner supply abnormality (K2)
F2-04
Toner cartridge improper (K2)
F2-05
Toner cartridge CRUM error (K2)
F2-39
Process thermistor trouble
F2-40
Toner empty sensor abnormality (K)
Trouble content
Communication error between the finisher and the
inserter
inserter
Section
PCU
Case 1
Cause
Malfunction due to electrical noises.
Check and
remedy
remedy
Turn ON/OFF the power to cancel the error.
Case 2
Cause
Connection trouble or disconnection of the
connector and the harness between the finisher
and the inserter. Finisher control PWB trouble,
inserter control PWB trouble
connector and the harness between the finisher
and the inserter. Finisher control PWB trouble,
inserter control PWB trouble
Check and
remedy
remedy
Check the connector and the harness in the
communication line. Replace the finisher control
PWB. Replace the inserter control PWB.
communication line. Replace the finisher control
PWB. Replace the inserter control PWB.
Trouble content
EEPROM trouble
Section
PCU
Case 1
Cause
EEPROM trouble, finisher control PWB trouble,
inserter control PWB trouble
inserter control PWB trouble
Check and
remedy
remedy
Replace the finisher control PWB.
Replace the inserter control PWB.
Replace the inserter control PWB.
Trouble content
Sensor adjustment failure
Section
PCU
Case 1
Cause
Sensor trouble, harness disconnection, finisher
control PWB trouble, inserter control PWB trouble
control PWB trouble, inserter control PWB trouble
Check and
remedy
remedy
Use SIM3-2 to check the operation of the inlet port
cover open/close sensor and the paper exit cover
open/close sensor.
Replace the finisher control PWB.
Replace the inserter control PWB.
cover open/close sensor and the paper exit cover
open/close sensor.
Replace the finisher control PWB.
Replace the inserter control PWB.
Trouble content
Toner end with the remaining quantity of 25% or
more.
The toner supply time exceeds 5 times as much as
the specified time.
more.
The toner supply time exceeds 5 times as much as
the specified time.
Section
PCU
Case 1
Cause
Toner motor section connector harness trouble
Check and
remedy
remedy
Check the connector connection of the toner motor
section.
Check the connector harness (TM) connection to
the main PWB.
section.
Check the connector harness (TM) connection to
the main PWB.
Case 2
Cause
Toner motor and toner density sensor trouble.
Piezoelectric sensor abnormality
Piezoelectric sensor abnormality
Check and
remedy
remedy
1)
Check the toner density sensor output.
(SIM25-1)
(SIM25-1)
2)
Check that the toner transport pipe is not
clogged between the toner cartridge and the
developing unit. Replace the toner cartridge
(CRUM) if necessary. Intermediate hopper
replacement
clogged between the toner cartridge and the
developing unit. Replace the toner cartridge
(CRUM) if necessary. Intermediate hopper
replacement
3)
If replacement of the toner cartridge (CRUM)
does not clear the trouble, check the
developing unit.
does not clear the trouble, check the
developing unit.
Trouble content
Improper data are detected in the CRUM contents
when the normal CRUM of the cartridge is
detected.
when the normal CRUM of the cartridge is
detected.
Section
PCU
Case 1
Cause
An improper cartridge is inserted.
Toner cartridge trouble
Toner cartridge trouble
Check and
remedy
remedy
Replace the toner cartridge.
Trouble content
CRUM cannot be read or written.
Section
PCU
Case 1
Cause
Connection trouble or disconnection of the
connector and the harness between the PCU and
the toner cartridge.
connector and the harness between the PCU and
the toner cartridge.
Check and
remedy
remedy
Check the connector and the harness between the
PCU and the toner cartridge.
PCU and the toner cartridge.
Case 2
Cause
CRUM trouble
Check and
remedy
remedy
Replace the toner cartridge.
Case 3
Cause
PCU PWB trouble
Check and
remedy
remedy
Replace the PCU PWB.
Trouble content
Process thermistor open
Section
PCU
Case 1
Cause
Process thermistor harness connection trouble
Check and
remedy
remedy
Check the connection of the harness and
connector of the process thermistor.
connector of the process thermistor.
Case 2
Cause
Process thermistor trouble
Check and
remedy
remedy
Check the connection of the harness and
connector of the process thermistor.
connector of the process thermistor.
Case 3
Cause
PCU PWB trouble
Check and
remedy
remedy
Check the PCU PWB.
Trouble content
Toner empty sensor output abnormality. Sample
level 25 or less or 231 or above.
level 25 or less or 231 or above.
Section
PCU
Case 1
Cause
The connector is not installed.
Check and
remedy
remedy
Check the connection of the connector harness to
the PCU PWB. Check the connection of the toner
empty sensor.
the PCU PWB. Check the connection of the toner
empty sensor.
Case 2
Cause
Connector harness trouble
Check and
remedy
remedy
Check the harness disconnection.
Case 3
Cause
Cartridge trouble
Check and
remedy
remedy
Check the cartridge connection.