MX-7001N  ADJUSTMENTS  6 – 8
Remark: By setting the default value, the specified voltage is 
normally outputted.
The adjustment value of each color mode is specified on the label
attached to the MC/DV high voltage power PWB. Enter that value.
DVK:XXX DVC:XXX DVM:XXX DVY:XXX
When the adjustment value (specified value) of the middle speed
mode is set, the adjustment values of the other modes are auto-
matically set according to the middle speed mode setting in a cer-
tain relationship.
To adjust all the modes individually, first adjust the middle speed
mode, then adjust the other mode.
If the middle speed mode is adjusted after adjustment of all the
modes individually, the adjustment values of the other modes are
automatically changed. Use care for that.
Therefore, unless there may be an abnormality in the output volt-
age, there is no need to check the output value.
If it must be checked that the normal voltage is outputted or if an
adjustment is required by referring to the output voltage, follow the
procedures below.
1)
Remove the screw, and remove the main unit rear cover.
2)
Open the PWB frame.
3)
Enter SIM8-1 mode.
4)
Select an output mode to be adjusted with the mode key and
the scroll key.
5)
Check the relationship between the pin No. of the connector
CNMON on the MC/DV high voltage PWB and each adjust-
ment mode.
6)
Apply a digital multi-meter to the connector CNMON pin on the
MC/DV high voltage PWB corresponding to the adjusted
mode.
7)
Press [EXECUTE] key.
The developing bias voltage is outputted for 30sec.
8)
Check the monitor voltage with the digital multi-meter.
If the monitor voltage is not in the range of the specified values
shown in the table above, change the adjustment value and
adjust again. If the specified value voltage is not obtained even
though the adjustment value is changed, the following parts
may be defective.
MC/DV high voltage PWB
PCU PWB
Developing unit
OPC drum unit
High voltage circuit electrode
 
6-C
Transfer voltage adjustment
This adjustment must be executed in the following cases:
* When the TC high voltage power PWB is replaced.
* When U2 trouble occurs.
* When the PCU PWB is replaced.
* When EEPROM on the PCU PWB is replaced.
1)
Enter SIM8-6 mode.
1
2
CNMON
1
or after 30 sec.
10-key
A : 78
;
TC1 LOW SPEED CL K
B : 78
;
TC1 MIDDLE SPEED CL K
C : 68
;
TC1 LOW SPEED CL C
D: 68
;
TC1 MIDDLE SPEED CL C
A:
SIMULATION NO.08-06
THV SETTING AND OUTPUT
XXX
0
255
OK
TEST
CLOSE
E : 68
;
TC1 LOW SPEED CL M
F : 68
;
TC1 MIDDLE SPEED CL M
G: 68
;
TC1 LOW SPEED CL Y
H: 68
;
TC1 MIDDLE SPEED CL Y
I : 78
;
TC1 LOW SPEED BW K
J : 78
;
TC1 MIDDLE SPEED BW K
K: 130
;
TC1 HIGH SPEED BW K
L : 132
;
TC2 PLAIN CL SPX
EXECUTE
EXECUTE
EXECUTE
A: 200
;
TC1 LOW SPEED CL K
B : 78
;
TC1 MIDDLE SPEED CL K
C : 68
;
TC1 LOW SPEED CL C
D: 68
;
TC1 MIDDLE SPEED CL C
A:
SIMULATION NO.08-06
THV SETTING AND OUTPUT
XXX
0
255
OK
TEST
CLOSE
E : 68
;
TC1 LOW SPEED CL M
F : 68
;
TC1 MIDDLE SPEED CL M
G: 68
;
TC1 LOW SPEED CL Y
H: 68
;
TC1 MIDDLE SPEED CL Y
I : 78
;
TC1 LOW SPEED BW K
J : 78
;
TC1 MIDDLE SPEED BW K
K: 130
;
TC1 HIGH SPEED BW K
L : 132
;
TC2 PLAIN CL SPX
EXECUTE