MX-7000N FAN, FILTER SECTION S – 6
4)
Remove the screws (H), and remove the inner ventilation fan
motor (Center) (I).
* When installing, direct the label face (J) to the mounting
motor (Center) (I).
* When installing, direct the label face (J) to the mounting
plate side, and position the harness (L) in mark (K) side.
(8) Inner ventilation fan motor (right)
1)
Remove the rear cabinet. (Refer to the "[A] EXTERNAL OUT-
FIT".)
FIT".)
2)
Remove the screws (A), and open the control box (B).
3)
Disconnect the connector (C), and remove the snap band (D).
4)
Close the control box (E).
5)
Remove the screw (F), and push the part (G), disengage the
pawl (H). Disengage the pawl (I), and remove the inner ventila-
tion fan motor (Right) unit (J).
pawl (H). Disengage the pawl (I), and remove the inner ventila-
tion fan motor (Right) unit (J).