MX-5500N, MX-6200N, MX-7000N (serv.man68). Drive Section-Detailed Section - Sharp Copying Equipment Service Manual (repair manual). Page 10

Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man68) Service Manual online

MX-7000N  DRIVE SECTION  Q – 10
f. Charger cleaner motor, CCM rotation detection
1)
Remove the rear cabinet. (Refer to the "[A] EXTERNAL OUT-
FIT".)
2)
Remove the main drive unit (BK). (Refer to the “(1) Main drive
unit (BK)”.)
3)
Disconnect the connector (A). Remove the harness (C) from
the pawls (B) of the motor fixing plate. Disconnect the connec-
tor (D). Remove the screws (E), and remove the motor fixing
plate (F). Disconnect the connector (G).
4)
Disconnect the connector (H). Remove the drive gear (I), the
charger cleaner motor (J), and the CCM rotation detection (K).
g. PTC cleaner motor
1)
Remove the rear cabinet. (Refer to the "[A] EXTERNAL OUT-
FIT".)
2)
Remove the main drive unit (BK). (Refer to the "(1) Main drive
unit (BK)".)
3)
Remove the transfer drive motor. (Refer to the "b. Transfer
dirve motor".)
4)
Remove the drum drive motor_K. (Refer to the "c. Drum drive
motor_K".)
5)
Remove the screws (A), and remove the terminal (white har-
ness) (B) and the terminal (red harness) (C).
* When installing, refer the mark (D) of the mounting plate,
arrange the terminals.
6)
Remove the screw (E), and remove the PTC electrode mount-
ing plate (F).
Unit
Parts
1
Main drive unit (BK)
g
Charger cleaner motor
h
CCM rotation detection
1-g
1-h
E
D
A
E
F
G
B
B
C
I
J
K
H
1-h
1-g
Unit
Parts
1
Main drive unit (BK)
i
PTC cleaner motor
1-i
A
A
B
C
D
E
F
Page of 32