MX-5500N, MX-6200N, MX-7000N (serv.man66). Fusing Section-Detailed section - Sharp Copying Equipment Service Manual (repair manual). Page 5

Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man66) Service Manual online

MX-7000N  FUSING SECTION  O – 5
2)
Remove the screws (A). Rotate the fusing web unit (B), and
remove it.
* When installing, engage the fusing web unit (B) to the pawls
(C) of the upper cover.
* When installing, be careful to prevent bending the elec-
trodes (D), and check that the electrodes are contacted.
3)
Remove the screws (E), and remove the upper cover (F).
4)
Disconnect the connectors (H) by releasing each locks (G).
Remove the screws (I), and remove the external thermostat
main  (J), the external thermostat sub (K), and the washers (L).
b. External thermistor main, External thermistor sub
1)
Remove the fusing unit.  (Refer to the "(1) Fusing unit".)
2)
Remove the screws (A). Rotate the fusing web unit (B), and
remove it.
* When installing, engage the fusing web unit (B) to the pawls
(C) of the upper cover.
* When installing, be careful to prevent bending the elec-
trodes (D), and check that the electrodes are contacted.
3)
Remove the screws (E), and remove the upper cover (F).
A
A
B
B
C
D
E
F
E
E
J
K
1-a
1-b
H
L
L
H
I
G
G
Unit
Parts
Mainte
nance
1
Fusing unit
c
External thermistor main
 ▲
d
External thermistor sub
 ▲
1-d
1-c
A
A
B
B
C
D
E
F
E
E
Page of 25
Display

Click on the first or last page to see other MX-5500N / MX-6200N / MX-7000N (serv.man66) service manuals if exist.