MX-5500N, MX-6200N, MX-7000N (serv.man49). ROM Version Up - Sharp Copying Equipment Service Manual (repair manual)

mx-5500n, mx-6200n, mx-7000n (serv.man49) service manual
Model
MX-5500N MX-6200N MX-7000N (serv.man49)
Pages
3 Few pages! See other manuals at the bottom of the first or last page.
Size
485.71 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / ROM Version Up
File
mx-5500n-mx-6200n-mx-7000n-sm49.pdf
Date

Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man49) Service Manual online

MX-7000N  ROM VERSION-UP  10 – 1
MX-7000N
Service Manual
 
[10] ROM VERSION-UP
1. General
A. Cases where version-up is required
ROM version-up is required in the following cases:
1)
When there is a necessity to upgrade the performance.
2)
When installing a new spare ROM to the machine for repair.
3)
When installing a new spare PWB unit with ROM installed to it.
4)
When there is a trouble in the programs in ROM and it must be
repaired.
B. Notes for version-up
(1) Relationship between each ROM and version-up
Before execution of ROM version-up, check combinations with
ROMís installed in the other PWBís including options.
Some combinations of versions may cause malfunctions of the
machine.
C. Update procedures and kinds of firmware
There are following methods of downloading of the firmware.
1)
Firmware download using media
2)
Firmware download using FTP
3)
Firmware download using Web page
• Firmware types
NOTE: If the MFPcnt PWB DIP SW No. 2 is not set to ON, an error
occurs.
2. Version-up procedure
A. Firmware download using media
(1) Firmware update from USB memory device
First you must install the firmware file (xxx.sfu) to the root of a
USB jump drive.
• If the firmware is in a folder, Simulation 49-01 cannot open
the folder.
• Secure Jumpdrive will not work.
• Must have a minimum of 32MB of storage capacity to load
the firmware onto it.
1)
Insert the USB memory device into the main unit.
2)
Enter the 49-01 screen. Press the button of the file to be
updated. The screen transfers to the update screen.
(In this screen, [FILE 1] is selected)
* The number of button changes depending on the number of
the file in the USB memory device inserted.
Flash ROM
Contents
Machine
ALL
ICU(BOOT)
ANIME
CONFIG
ESCP_FONT
PDL_FONT
ANIMATION
COLOR PROFILE
GRAPHIC
SLIST
ICU(MAIN)
ICU(MAIN)
IMG-ASIC
IMAGE DATA
SCU
SCU(MAIN)
PCU
PCU(MAIN)
DSPF
DSPF(MAIN)
Option
FAX
FAX OPTION(MAIN)
4K FINISHER
4KFIN(MAIN)
SADDLE UNIT
SADDLE(MAIN)
INSERTER
INSERTER(MAIN)
A3 LCC
A3LCC(MAIN)
A4 LCC
A4LCC(MAIN)
+
USB Memor y
USB Host
Firmware.
Firmware.sfu
Firmware.
Media
Adapter
Firmware.
The machine recognizes the
media and automatically executes
processing.
SIMULATION NO.49-01
TEST
FIRMWARE UPDATE/usbbd00/**********/
FILE1
FILE2
FILE3
FILE4
1/1
CLOSE
..
MX-7000N  ROM VERSION-UP  10 – 2
3)
Current version number and the version number to be updated
will be shown for each firmware respectively.
Following key-codes will be changed;
NOW 
→ CURRENT
NEXT 
→ UPDATED TO
4)
Select the button of the firmware to be updated. The button will
be highlighted. (In this screen, [ICU(MAIN)] and [LANGUAGE]
are selected.) At the same time, [EXECUTE] button appears.
* Press the selected button again to release the selection.
* Press [ALL] button to select all items.
5)
Press [EXECUTE] button. “ARE YOU SURE? [YES] [NO]”
becomes clear. If no button is selected, [EXECUTE] button is
gray out and cannot be pressed. Press [YES] to start the
update.
6)
At the completion of the upgrade, the display will change to: 
"COMPLETE: PLEASE TOUCH [OK] TO FINISH" Press OK.
The Imager will reboot at this time.
7)
Go to Simulation 22-05 and confirm the firmware has
upgraded successfully.
Note: If the Imager locks up or loses power during the
upgrade, it could corrupt the firmware, preventing the
imager from booting up normally.  If this occurs, you can
"rescue" the firmware using the following procedure:
• Rename the firmware file on the USB device to emup-
date.sfu
• Power off the imager (both switches) and insert the USB
device (Jumpdrive) into the USB port of the imager.
• Power on the imager
• The Imager will boot up into emergency update mode.
When finished, the display will read "update completed"
• Power off the imager, and remove the USB device
• Reboot the imager, and go simulation 22-05 to confirm
firmware has upgraded successfully.
CLOSE
SIMULATION NO.49-01
TEST
FIRMWARE UPDATE
ICU(MAIN)
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
1/3
ICU(BOOTM)
CURRENT 09.00.00.00
UPDATED TO 01.00.00.00
:
ICU(BOOTS)
CURRENT 01.01.00.00
UPDATED TO 09.00.00.00
:
LANGUAGE
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
GRAPHIC
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
SLIST
CURRENT 09.00.00.00
UPDATED TO 01.00.00.00
:
PCU(BOOT)
CURRENT 01.01.00.00
UPDATED TO 09.00.00.00
:
PCU(MAIN)
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
DESK(BOOT)
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
A4LCC(BOOT)
CURRENT 01.01.00.00
UPDATED TO 09.00.00.00
:
DESK(MAIN)
CURRENT 01.01.00.00
UPDATED TO 09.00.00.00
:
CONFIG
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
ARE YOU SURE?
YES
NO
EXECUTE
ALL
CLOSE
SIMULATION NO.49-01
TEST
FIRMWARE UPDATE
ICU(MAIN)
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
1/3
ICU(BOOTM)
CURRENT 09.00.00.00
UPDATED TO 01.00.00.00
:
ICU(BOOTS)
CURRENT 01.01.00.00
UPDATED TO 09.00.00.00
:
LANGUAGE
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
GRAPHIC
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
SLIST
CURRENT 09.00.00.00
UPDATED TO 01.00.00.00
:
PCU(BOOT)
CURRENT 01.01.00.00
UPDATED TO 09.00.00.00
:
PCU(MAIN)
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
DESK(BOOT)
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
A4LCC(BOOT)
CURRENT 01.01.00.00
UPDATED TO 09.00.00.00
:
DESK(MAIN)
CURRENT 01.01.00.00
UPDATED TO 09.00.00.00
:
CONFIG
CURRENT 01.00.00.00
UPDATED TO 01.01.00.00
:
ARE YOU SURE?
YES
NO
EXECUTE
ALL
COMPLETE㧦PLEASE TURN MAIN POWER OFF THEN ON
SIMULATION NO.49-01
TEST
FIRMWARE UPDATE
CLOSE
S
E
CAUTION DO NOT POWER OFF THE MFP! FIRMWARE UPDATE IN PROGRESS!
COMPLETE : PLEASE TOUCH [OK] TO FINISH.
SIMULATION NO.49-01
TEST
FIRMWARE UPDATE
CLOSE
OK
ERROR
: PLEASE TOUCH [OK] TO FINISH.
SIMULATION NO.49-01
TEST
FIRMWARE UPDATE
CLOSE
ICUM,PCU,SCU
OK
MX-7000N  ROM VERSION-UP  10 – 3
B. Firmware download using FTP
FTP software is used to transfer the firmware data (extension “.sfu”) from the PC to the machine. The controller recognizes the firmware identi-
fier and the machine automatically switches to firmware write mode. After the firmware is updated, the machine automatically resets.
C. Firmware download using Web page
A Web browser (service technician’s Web page) is used to update
the firmware.
Update procedure
1)
Start the Web browser on a PC and enter the specified URL. A
special firmware upgrade page appears.
2)
Click the “Update of Firmware” button in the Web page. Click
the “Browse” button and select the firmware for the update.
3)
After selecting the file, click the “Submit” button to send the
firmware to the Renaissance machine.
Update processing begins. While processing takes place,
“Firmware Update, now processing...” appears.
4)
When the firmware update is finished, “Firmware Update com-
pleted. Please reboot the MFP.” appears. Pressing the
[Reboot] key, the machine will restart to complete the update.
The browser will shift to the following screen.
“Close the browser and open again to display latest informa-
tion.” will be displayed.
5)
Update is completed with the above procedures.
FTP Client
Machine 2
Machine 4
Firmware.sfu
Machine 1
10.36.112.83
Machine 3
10.36.112.84
10.36.101.52
10.36.112.83
MX-7000N
Page of 3
Display

Download Sharp MX-5500N / MX-6200N / MX-7000N (serv.man49) Service Manual (Repair Manual)

Here you can read online and download Sharp MX-5500N / MX-6200N / MX-7000N (serv.man49) Service Manual in PDF. MX-5500N / MX-6200N / MX-7000N (serv.man49) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp MX-5500N / MX-6200N / MX-7000N (serv.man49) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.