MX-5500N, MX-6200N, MX-7000N (serv.man45). Adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp MX-5500N / MX-6200N / MX-7000N (serv.man45) Service Manual online

MX-7000N  ADJUSTMENTS  6 – 11
 
7-B
Color image density sensor, black image 
density sensor, image registration sensor 
adjustment
1)
Enter SIM44-2 mode.
2)
Press [EXECUTE] key.
The color image density sensor, the black image density sen-
sor, and the image registration sensor are automatically
adjusted.
After completion of the adjustment, the adjustment result is
displayed and [EXECUTE] key returns to the normal display.
If the adjustment is not completed normally, "ERROR" is dis-
played.
In that case, check the following sections for any abnormality.
If any abnormality is found, repair and adjust again.
If an error occurs, the adjustment result is not revised.
* Color image density sensor
* Black image density sensor
* Image registration sensor
* PCU PWB
* Transfer belt (dirt, scratch)
* Transfer belt cleaner
PROCON GAIN ADJUSTMENT
EXECUTE
PCS_CL LED ADJ
21
:
PCS_K LED ADJ
21
:
1/2
SIMULATION NO.44-02
TEST
CLOSE
PCS_K BELT DIF
0
:
PCS_CL DARK
0
:
PCS_K DARK
0
:
PCS_K GRND
0
:
PCS_K BELT MAX
0
:
PCS_K BELT MIN
0
:
REG_F LED ADJ
27
:
REG_R LED ADJ
27
:
REG_F DARK
0
:
REG_R DARK
0
:
REG_F GRND
0
:
REG_R GRND
0
:
REG_F BELT MAX
0
:
REG_F BELT MIN
0
:
REG_F BELT DIF
0
:
REG_R BELT MAX
0
:
REG_R BELT MIN
0
:
REG_R BELT DIF
0
:
Display/Item
Content
Adjustment value range
Default value
PROCON
A
PCS_CL LED ADJ
Color image density sensor light emitting quantity adjustment value
1 – 255
21
B
PCS _K LED ADJ
Black image density sensor light emitting quantity adjustment value
1 – 255
21
C
PCS_CL DARK
Color image sensor dark voltage
0 – 255
0
D
PCS_K DARK
Black image density sensor dark voltage
0 – 255
0
E
PCS_K GRND
Belt base detection level when completion of Item B adjustment 
0 – 255
0
F
PCS_K BELT MAX
Belt base detection level (Max.)
0 – 255
0
G
PCS_K BELT MIN
Belt base detection level (Min.)
0 – 255
0
H
PCS_K BELT DIF
Belt base detection level difference (Item E, Item F)
0 – 255
0
REGIST
I
REG_F LED ADJ
Image registration sensor light emitting quantity adjustment value F
1 – 255
27
J
REG_R LED ADJ
Image registration sensor light emitting quantity adjustment value R
1 – 255
27
K
REG_F DARK
Image registration sensor dark voltage F
0 – 255
0
L
REG_R DARK
Image registration sensor dark voltage R
0 – 255
0
M
REG_F GRND
Belt base detection level when completion of Item I adjustment 
0 – 255
0
N
REG_R GRND
Belt base detection level when completion of Item J adjustment
0 – 256
0
O
REG_F BELTMAX
Belt base detection level (Max.) F
0 – 255
0
P
REG_F BELT MIN
Belt base detection level (Min.) F
0 – 255
0
Q
REG_F BELT DIF
Belt base detection level difference (Item O, Item P)
0 – 255
0
R
REG_R BELT MAX
Belt base detection level (Max.) R
0 – 255
0
S
REG_R BELT MIN
Belt base detection level (Min.) R
0 – 255
0
T
REG_R BELT DIF
Belt base detection level difference (Item R, Item S)
0 – 255
0
U
REG_F PATCH (K)
Patch detection level  F (K)
0 – 255
0
V
REG_F PATCH (C)
Patch detection level  F (C)
0 – 255
0
W
REG_F PATCH (M)
Patch detection level  F (M)
0 – 255
0
X
REG_F PATCH (Y)
Patch detection level  F (Y)
0 – 255
0
Y
REG_R PATCH (K)
Patch detection level  R (K)
0 – 255
0
Z
REG_R PATCH (C)
Patch detection level  R (C)
0 – 255
0
AA
REG_R PATCH (M)
Patch detection level  R (M)
0 – 255
0
AB
REG_R PATCH (Y)
Patch detection level  R (Y)
0 – 255
0
Page of 76
Display