Read Sharp MX-5050N / MX-5050V / MX-5070N / MX-5070V / MX-6050N / MX-6050V / MX-6070N / MX-6070V Handy Guide online
SHARP
INITIAL SETUP
11
DEVELOPER SETUP:
From April 2016 production onwards, CMYK Developer is pre-installed by the factory
therefore, Sim25-02 Auto Developer Adjustment should not be executed.
It is recommended to execute Sim25-01 (Developer Stir), prior to installing toner.
therefore, Sim25-02 Auto Developer Adjustment should not be executed.
It is recommended to execute Sim25-01 (Developer Stir), prior to installing toner.
Only execute Sim25-02 if CMYK Developer has not been pre-installed.
Clean LSU Dust Proof Glass.
TONER INSTALLATION & REPLENISHMENT:
Install CMYK Toner Cartridges:
Caution:
DO NOT open any Exterior Cover, Power OFF/ON or enter Simulation
Mode during Initial Toner Replenishment.
PRODUCT ACTIVATION & FIRMWARE UPGRADE:
Activation of Optional Products:
System Settings – Common Settings – Product Key.
Sim 22-05 Check Firmware Version(s):
Upgrade to latest version.
INITIAL SETUP:
Sim 26-01
Right Exit Tray Installation: Yes/No.
Sim 26-02
LCC Installation (Paper Size): A4/Letter.
Sim 26-06
Machine Destination check.
Sim 26-35
Set Multi Error Counter: Set to 1 (Multi Count).
Sim 26-50
Long Paper Support (up to 1300mm): 0 = Disable, 1 = Enable.
Sim 26-52
Non Printed Paper Counter Set-up.
Sim 55-01
Primary Transfer Belt lubrication
[MX-5050N/6050N only]:
Check SSW 12-4 is set to 1 (enable lubrication at specific interval).
Check SSW 27-4 is set to 1 (force lubrication @ maintenance).
Note: Above SSW settings are applied when PCU v05.00.Z1.00 is installed.
Sim 55-03
Process Mixed Size Pages (orientation) when Printing in Duplex:
SSW 3-6, 0 = Disable, 1 = Enable.
Sim 55-03
PDF/PS Preview Thumbnail for Direct Print Function [MX-PK13 required]:
SSW 34-3, 0 = Disable, 1 = Enable.
Add PANTONE® Colour LUT
Service WebPage – Output Profile Settings – Spot Colour Table Settings;
Upload PANTONE® LUT for CR4 series.
Adjust Date/Time (Inc. Daylight Saving setting):
System Settings – Common Settings – Clock Adjust.
Click on the first or last page to see other MX-5050N / MX-5050V / MX-5070N / MX-5070V / MX-6050N / MX-6050V / MX-6070N / MX-6070V service manuals if exist.