MX-6070N SIMULATION 6 – 19
7-6
Purpose
Setting
Function (Purpose)
Used to set the operating intermittent aging
cycle.
cycle.
Section
Operation/Procedure
1) Enter the intermittent aging operation cycle (unit: sec) with 10-
1) Enter the intermittent aging operation cycle (unit: sec) with 10-
key.
2) Press [OK] key.
The time entered in procedure 1) is set.
* The interval time that can be set is 1 to 900 (sec).
* The interval time that can be set is 1 to 900 (sec).
The aging operation condition set by this mode is maintained here-
after unless the power is turned off or the setting is changed.
after unless the power is turned off or the setting is changed.
7-8
Purpose
Operation display
Function (Purpose)
Used to display the warm-up time.
Section
Operation/Procedure
Press [EXECUTE] key.
Counting of the warm-up time is started and the time required for
warm-up is displayed
* Interruption of counting by pressing [EXECUTE] key is inhibited.
Press [EXECUTE] key.
Counting of the warm-up time is started and the time required for
warm-up is displayed
* Interruption of counting by pressing [EXECUTE] key is inhibited.
7-9
Purpose
Operation test/check
Function (Purpose)
Color setting in the color copy test mode
(Used to check the copy operation and the
image quality for each color).
(Used to check the copy operation and the
image quality for each color).
Section
Operation/Procedure
1) Select the copy color with the touch panel key.
1) Select the copy color with the touch panel key.
(Two or more colors can be selected.)
The key of the selected color is highlighted.
The key of the selected color is highlighted.
2) Press [EXECUTE] key.
Copying is performed with the selected color.
When [CLOSE] key is pressed, the display goes into the copy oper-
ation menu in the simulation mode.
ation menu in the simulation mode.
7-12
Purpose
Operation test/check
Function (Purpose)
The document reading number of sheets
setting (for aging operation)
setting (for aging operation)
Section
SPF
Operation/Procedure
1)
1)
Set document reading quantity with 10-key.
(Setting range:0 - 255)
(Setting range:0 - 255)
2)
Press [OK] key. The set value is saved.
The aging operation condition set by this mode is maintained here-
after unless the power is turned off or the setting is changed.
after unless the power is turned off or the setting is changed.
8
8-1
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operations of
the developing voltage in each print mode
and the control circuit.
* When the middle speed is adjusted, the
low speed are also adjusted simultane-
ously.
the developing voltage in each print mode
and the control circuit.
* When the middle speed is adjusted, the
low speed are also adjusted simultane-
ously.
Section
Process (Developing)
Operation/Procedure
1)
1)
Select a speed with [MIDDLE] and [LOW] keys on the touch
panel.
panel.
2)
Select a target item to be adjusted with scroll keys.
3)
Enter the setting value with 10-key. (The value specified on the
label of the high voltage PWB must be entered.)
* When the r s key is pressed, the setting value of each item
label of the high voltage PWB must be entered.)
* When the r s key is pressed, the setting value of each item
can be changed with 1up (1down) collectively.
4)
Press [OK] key. Press [OK] key. The set value is saved.
MISFEED DISABLE
JAM detection ignoring setting
FUSING DISABLE
Fusing unit ignoring setting
WARMUP DISABLE
Warming up ignoring setting
DV CHECK DISABLE
Developing unit ignoring setting
SHADING DISABLE
Shading correction operation omitting setting
CCD GAIN FREE
CCD gain adjustment omitting setting
K
Setup/cancel of black
C
Setup/cancel of cyan
M
Setup/cancel of magenta
Y
Setup/cancel of yellow
Item/Display (Mode)
Content
Adjustment
range
Actual
voltage
MIDDLE
A
MIDDLE
SPEED
DVB_K
SPEED
DVB_K
Developing
bias voltage
(Middle
speed mode)
bias voltage
(Middle
speed mode)
K
0 - 600
–450V
+/- 5V
B
MIDDLE
SPEED
DVB_C
SPEED
DVB_C
Developing
bias voltage
(Middle
speed mode)
bias voltage
(Middle
speed mode)
C
0 - 600
–450V
+/- 5V
C
MIDDLE
SPEED
DVB_M
SPEED
DVB_M
Developing
bias voltage
(Middle
speed mode)
bias voltage
(Middle
speed mode)
M
0 - 600
–450V
+/- 5V
D
MIDDLE
SPEED
DVB_Y
SPEED
DVB_Y
Developing
bias voltage
(Middle
speed mode)
bias voltage
(Middle
speed mode)
Y
0 - 600
–450V
+/- 5V
LOW
A
LOW
SPEED
DVB_K
SPEED
DVB_K
Developing
bias voltage
(Low speed
mode)
bias voltage
(Low speed
mode)
K
0 - 600
–450V
+/- 5V
B
LOW
SPEED
DVB_C
SPEED
DVB_C
Developing
bias voltage
(Low speed
mode)
bias voltage
(Low speed
mode)
C
0 - 600
-450V
±5V
C
LOW
SPEED
DVB_M
SPEED
DVB_M
Developing
bias voltage
(Low speed
mode)
bias voltage
(Low speed
mode)
M
0 - 600
-450V
±5V
D
LOW
SPEED
DVB_Y
SPEED
DVB_Y
Developing
bias voltage
(Low speed
mode)
bias voltage
(Low speed
mode)
Y
0 - 600
-450V
±5V
Click on the first or last page to see other MX-5050N / MX-5050V / MX-5070N / MX-5070V / MX-6050N / MX-6050V / MX-6070N / MX-6070V (serv.man6) service manuals if exist.