MX-6070V  EXTERNAL VIEW AND INTERNAL STRUCTURE  4 – 8
B. Sensors and switches
Signal name
Name
Type
Function and Operation
SCOV
Upper door open/close sensor
Transmission type
Detects open/close of the upper door
SLCOV
Lower door open/close sensor
Micro switch
Detects open/close of the lower door
SOCD
DSPF open/close sensor
Transmission type
Detects open/close of the DSPF unit
SPED1
Document empty sensor
Transmission type
Detects document empty in the document feed tray
SPED2
Document empty sensor
Transmission type
Detects document empty in the document feed tray
SPLS1
Document length detection short sensor
Transmission type
Detects the document length of the document feed tray upper
SPLS2
Document length detection long sensor
Transmission type
Detects the document length of the document feed tray upper
SPOD
Document exit sensor
Transmission type
Detects document exit of the document
SPPD1
Document pass sensor 1
Transmission type
Detects pass of the document
SPPD2
Document pass sensor 2
Reflection type
Detects pass of the document
SPPD3
Document pass sensor 3
Transmission type
Detects pass of the document
SPPD4
Document pass sensor 4
Transmission type
Detects pass of the document
SPPD5
Document pass sensor 5
Transmission type
Detects pass of the document
SPRDMD
Document random sensor
Transmission type
Detects the document size in random document feed
SPWS
Document width sensor
Volume type resistor
Detects the document width of the document feed tray upper
STLD
Document feed tray lower limit sensor
Transmission type
Detects the lower limit of the document feed tray
STUD
Document feed tray upper limit sensor
Transmission type
Detects the upper limit of the document feed tray
SCOV
SLCOV
SOCD
SPLS1
SPWS
SPLS2
SPED2
SPOD
SPPD1
SPPD2
SPPD3
SPPD4
SPPD5
SPRDMD
STLD
STUD
SPED1