REPAIR HINTS 
SHARP  
 
78
 
TROUBLE CODES
 
MX-5070N 
MX-6070N 
C1-01/03/05/07 trouble during MC 
cleaning 
Update the MFP Firmware to 05.11.Z1.00 (or higher) 
ALL 
E7-03, E7-90 trouble and/or Indication 
of Toner Quantity [0%] during MFP 
startup. 
MX-5070N 
MX-6070N 
F2-65 trouble during continuous run 
operation 
ALL 
Intermittent F1-00 trouble 
Update the PCU Firmware to 05.00.Z1.00 and MXFN27 
Inner Firmware to 01.03.Z1.a0 (or higher). 
MX-FN27 
Intermittent F1-04 or F1-22 Errors 
This may be due to the Paddle Drive Clutch not reversing 
to allow the paddles to return to their home position. 
Replace the following parts (MXFN27 PG Section 3):- 
0CWFE360460// (Item 7 - Clutch) x 2. 
0CWFU207660// (Item 13 - Gear) x 2. 
0CWFU207670// (Item 14 - Pulley) x 1. 
Note: There are two clutches that need to be replaced 
(Item 7 & 13), but only 1 Pulley is required (Item 14). 
ALL 
Intermittent H4-00, only when the 
Motion Sensor is enabled 
Upgrade the PCU firmware to 04.00.Z1.00 (or higher). 
ALL 
L4-11 
The MX-TU16 Centre Exit Tray Unit is supplied with a 
drive assembly that must be installed to enable the offset 
shifter to operate. Without the Centre Exit Tray Unit,  
L4-11 trouble will be displayed if no finishing option is 
installed (MX-FN27 or MX-FN29/31 with MXRB25).  
As a temporary measure, changing SIM55-01, SW24-7 
from 0 to 1 will allow machine operation without an 
option finisher however, this soft switch MUST be set 
back to 0 (default) once the Finisher is reinstalled. 
 
IMAGE SEND
 
ALL 
Using Blank Page Skip function, is it 
possible to disable the number of 
pages sent confirmation message? 
It is not possible to disable the confirmation message. 
However, to prevent the cancellation of a scan job if OK is 
not pressed from the confirmation message, change the 
following SW setting:- 
SIM66-1, SSW 95, Data 7 from 0 to 1 
MX-FX15 
When unpacking the MX-FX15  
Fax Expansion Kit, there is no line cord 
included? 
The line cord is no longer supplied with the MX-FX15. 
Use the line cord from the existing machine, or the  
MX-FX13 line cord may be ordered and used. 
Note: Line cords are supplied for UK, German & French 
markets only. 
ALL
 
How to setup scan to Office 365 email 
from the Sharp MFP? 
Check the following settings under System Settings -> 
Network Settings -> Service Settings -> SMTP:- 
Primary Server: smtp.office365.com 
Port Number: 587 
Sender Address: ****@onmicrosoft.com 
SSL: ON 
SMTP Authentication: ON 
 
 