Read Sharp MX-4140N / MX-4141N / MX-5140N / MX-5141N (serv.man75) Technical Bulletin online
Sharp Electronics (UK) Ltd., Document Systems Support
1/3
Date:
19
th
of February 2015
Model:
See below
Ref.:
CCE1421
Colour:
White
Page:
1 of 3
TECHNICAL BULLETIN
ROM UPGRADE ..... (3).
1. Model Name:
MX-FR42U(Optional for MX-4140N/4141N/5140N/5141N)
2. Description:
Upgrade of ICUM-ROM
From January 2015 production
ROM control No.
ICUM
C00 0300Rd
Changed item: See the attached file
Note) This report is a T/R for the data security kit option, corresponding to general
T/R No. CCE-1405R
T/R No. CCE-1405R
ROM version history table
No.
ROM control No.
ICUM
Action
T/R No.
(2) B01 0202Rd
2014/6
CCE-1324
(1) B00 0200Rd
2014/1
Mid
CCE-1263
Sharp Electronics (UK) Ltd., Document Systems Support
2/3
[Description]
No. Item
Details
1
Specification
Support for Scan accessory kit MX-AP14
2
Main unit control
Modification of U7 trouble due to excess amount of time required for activation process to
register vast amount of job log
register vast amount of job log
3
Main unit control
Modification of L8-20 which may occur when condition signaling between internal
modules is not done properly.
modules is not done properly.
4
Main unit control
Modification of a problem which occurs with following steps: 1) Print out a test pattern in
Paper Settings from Bypass tray in duplex. 2) The Bypass tray gets empty 3) Add papers
to the bypass tray. 4) The test pattern is printed in simplex.
Paper Settings from Bypass tray in duplex. 2) The Bypass tray gets empty 3) Add papers
to the bypass tray. 4) The test pattern is printed in simplex.
5
Main unit control
Modification of L8-20 error which may occur while printing the data with USB connection
to PC
to PC
6
Main unit control
Modification of a failure to turn to Ready state and machine lock up etc.
The problems occurs because the module which controls real-time clock (RTC) in ICU is
not activated properly.
The problems occurs because the module which controls real-time clock (RTC) in ICU is
not activated properly.
7
Main unit control
Modification of a failure to restart the unit properly while acquiring the image (snapshot)
during the firmware upgrade due to lack of some data necessary.
during the firmware upgrade due to lack of some data necessary.
8
Main unit control
Modification of Scan job which keep remaining internally. The problem occurs if Eco scan
setting was enabled but canceled after previewing for Copy job.
setting was enabled but canceled after previewing for Copy job.
9
Main unit control
Modification of discontinuance of Fax data transmission due to limitation and deletion of
Print job.
These problem may occur due to the improper internal processing for job completion.
Print job.
These problem may occur due to the improper internal processing for job completion.
10 UI
Modification to allow enable/disable "Default Verification Stamp" setting in each mode
separately. (Now it is allowed to set for Fax/I-Fax mode and other modes.)
separately. (Now it is allowed to set for Fax/I-Fax mode and other modes.)
11 UI
Modification of a failure to delete the job completed from Job Status (Direct print from
USB flash drive). User cannot delete the job on the Job Status screen.
USB flash drive). User cannot delete the job on the Job Status screen.
12 OSA
Modification of an error to activate Fax OSA application after recovering from power save
mode
mode
13 Printer
Modification of machine lock up which occurs while spooling particular data including
JPEG image
JPEG image
14
Printer
Modification of a failure to print out particular Excel data which includes TIFF image
15 Printer
Modification of overlapped characters which may appear when data are printed directly
from USB flash drive.
from USB flash drive.
16
Printer
Modification of garbled characters which may appear during the direct print of PDF file
17
Printer
Modification of a failure to print out particular PDF data directly from USB flash drive
18 Printer
Modification of termination of printing particular PDF file without printing entire file. Even
when the data are printed, the print process takes too long.
when the data are printed, the print process takes too long.
19 Printer
Modification of a failure to process large amount of data with raster pattern. The unit
displays "Rendering" and never output the data.
displays "Rendering" and never output the data.
20 Printer
Modification of machine lock up which occurs while printing particular or large volume PS
file.
file.
21 Printer
Modification of occasional image rotation of page 2.
It rotates by 90 degrees while printing a PS file.
It rotates by 90 degrees while printing a PS file.
22 Printer
Modification of machine lock up/ printing failure which occurs while printing particular PS
file.
file.
23 Printer
Modification of problems with Network printing, such as 1) paper jam which is not logged
in Jam History, 2) machine lockup rejecting key operations
in Jam History, 2) machine lockup rejecting key operations
24 Printer
Modification of Control panel stops responding after completing a batch print of several
PS files (which includes the data in duplex printing)
PS files (which includes the data in duplex printing)
25 Printer
Remedy for delay in printing due to the standby time between jobs while printing several
jobs in series
jobs in series
26 Printer
Addition of Controller Soft SW settings. Modification is made so that when Bypass Tray
Settings > Size Input is set to "X=148 / Y=210", the image is rotated by 90 degrees.
SIM55-3 Soft SW 33-4
0: Disabled (Default)
1: Enabled
Settings > Size Input is set to "X=148 / Y=210", the image is rotated by 90 degrees.
SIM55-3 Soft SW 33-4
0: Disabled (Default)
1: Enabled
Sharp Electronics (UK) Ltd., Document Systems Support
3/3
No. Item
Details
27
Printer
Modification of missing image found on custom-sized envelope
28 Printer
Modification of "ERROR: Limitcheck OFFENDING COMMAND" which appears while
printing particular Excel sheet from Mac OSX10.9.3.
printing particular Excel sheet from Mac OSX10.9.3.
29 Printer
Modification of printing objects with different color which occurs while printing from
AS400.
AS400.
30 Printer
Modification of problem with printing smooth transition of gradation in light gray
The problem occurs while printing InDesign data from MacOS10.6.8.
The problem occurs while printing InDesign data from MacOS10.6.8.
31 Network
Modification has been made to enhance the security level for Web access.
Following features have been added/changed to perform after the log-in with [User
Authority: users] or [Administrator Authority: admin]
- Add User Authority (Login Name: User).
- Change the top screen when accessing the web page to Loin screen.
Initial values of access authority and password for User and login Administrator are as
below:
*Access Authority
User Authority (added): Same as the existing operation which can perform on Top
screen.
Administrator Authority: Same as the existing administrator login authority.
*Initial value of password for each authority
User Authority: users
Administrator Authority: admin
*Inheritance of the password already set up
If the passwords for the administrator and user have already set up before updating the
firmware, the passwords already set up will be inherited after the firmware update.
(*Passwords for the administrator and user have already set up will not be reset.)
*Enable/disable the additional features
Those features will be enabled once this firmware is applied.
For the setting change, those features can be switched between ON and OFF on the
setup item of the main unit or by checking/unchecking the checkbox of “Restrict Device
Web Page Access Via Password” in “Security Settings” on the top page of Web page.
Checked: ON
Unchecked: OFF
Default: Japanese market=ON, Overseas markets: OFF
Following features have been added/changed to perform after the log-in with [User
Authority: users] or [Administrator Authority: admin]
- Add User Authority (Login Name: User).
- Change the top screen when accessing the web page to Loin screen.
Initial values of access authority and password for User and login Administrator are as
below:
*Access Authority
User Authority (added): Same as the existing operation which can perform on Top
screen.
Administrator Authority: Same as the existing administrator login authority.
*Initial value of password for each authority
User Authority: users
Administrator Authority: admin
*Inheritance of the password already set up
If the passwords for the administrator and user have already set up before updating the
firmware, the passwords already set up will be inherited after the firmware update.
(*Passwords for the administrator and user have already set up will not be reset.)
*Enable/disable the additional features
Those features will be enabled once this firmware is applied.
For the setting change, those features can be switched between ON and OFF on the
setup item of the main unit or by checking/unchecking the checkbox of “Restrict Device
Web Page Access Via Password” in “Security Settings” on the top page of Web page.
Checked: ON
Unchecked: OFF
Default: Japanese market=ON, Overseas markets: OFF
32 Network
Factory default of LPD timeout period is changed from 0 (infinite) to 90 sec.
*The value above will not be changed when updating the firmware in the field.
*The value above will not be changed when updating the firmware in the field.
33
Network
Modification of an error to authenticate IEEE802.1X for wired LAN
34
Network
Enabling display of Machine ID information in MIB