1. Remove Interface unit from the main unit of the machine.
2. From the upper and lower side indicated by arrows, check that the grease (FLOIL G313S)
UKOG-0307FCZZ is applied to the inner/outer side of the spring. If not applied, please apply it.
3. Remove E-ring and sintered bearing at the rear side.
Upper side
Lower side
Check the grease on upper side.
Remove E-ring.
Remove sintered bearing.
Check the grease on lower side.
Click on the first or last page to see other MX-4140N / MX-4141N / MX-5140N / MX-5141N (serv.man112) service manuals if exist.