Firmware Recovery Procedure 
 
 
28 
Document Solutions After Sales Service 
 
 
 
 
 
 
 
 
 
 
 
The following five keys are used for executing functions when in the CN Update mode 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.
  Insert the USB memory containing the firmware into the USB port 
 
2.
  Turn on the power 
 
3.
  Check to confirm the machine starts booting (It takes more than 
10 seconds to display the menu) 
 
              
 
In the event of a power failure during a firmware update or HDD failure, the machine may fail to reboot because of 
corrupted firmware. In this case the SD card containing the correct BOOT program will have to be replaced, 
firmware will then have to be recovered using the CN method. 
 
 
Firmware Recovery Procedure: 
To enter the CN firmware recovery method, turn ON the UPDATE DIP-SW on the MFP PWB  
 
 
 
 
 
OK key 
MENU key 
BACK key 
UP key 
DOWN key 
 
Display when Booting is complete 