Read Sharp MX-4110N / MX-4111N / MX-4112N / MX-4110FN / MX-4111FN / MX-5110N / MX-5111N / MX-5112N / MX-5110FN / MX-5111FN (serv.man132) Technical Bulletin online
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-982
Note: When to make the setup change, change the entire items on the Setup Details column for Sim43-1
and 43-4 as listed on the table below, not individually make a change on the item.
[Setup Details]
- MX4112N
Fusing Temperature Setup Point
Fusing Temperature Setup Point
SW-A
SW-B
Ite
m
s
Setup Details
Set within the range for each
item.
Do not set outside this range
item.
Do not set outside this range
Set within the range for each
item.
Do not set outside this range
item.
Do not set outside this range
(1)
Fac
tor
y def
aul
t
val
ue
(2)
(1)
Fac
tor
y def
aul
t
val
ue
(2)
MX
4112N
S
im
43
-1
A Ready standby TH_UM set value
155
160
165
165
170
175
B Ready standby TH_LM set value
100
100
105
100
105
110
C Ready standby TH_US set value
165
170
175
175
180
185
D Black-White plain paper TH_UM set value
150
155
160
160
165
170
E Black-White plain paper TH_LM set value
95
100
105
100
105
110
F Black-White plain paper TH_US set value
150
155
160
160
165
170
G Color plain paper TH_UM set value
160
165
170
170
175
180
H Color plain paper TH_LM set value
95
100
105
100
105
110
I Color plain paper TH_US set value
160
165
170
170
175
180
Y Preheating TH_UM set value
130
135
140
130
135
140
Z Preheating TH_US set value
140
145
150
140
145
150
AB Preheating TH_LM set value
100
100
105
100
100
105
AF TH_UM set value when Warm-Up at 120°C or below
160
165
170
170
175
180
AG TH_LM set value when Warm-Up at 120°C or below
95
100
105
100
105
110
AH TH_US set value when Warm-Up at 120°C or below
160
165
170
170
175
180
AJ TH_UM set value when Warm-Up at 120°C or above
160
165
170
170
175
180
AK TH_LM set value when Warm-Up at 120°C or above
95
100
105
100
105
110
AL TH_US set value when Warm-Up at 120°C or above
160
165
170
170
175
180
AP
Job enable TH_UM temperature when Warm-Up at
alpha °C or above
alpha °C or above
160
165
170
170
175
180
AR
Job enable TH_UM temperature when Warm-Up at
alpha °C or below
alpha °C or below
160
165
170
170
175
180
AT
Job enable temperature (B/W) when the upper roller
temperature is lower than alpha °C
temperature is lower than alpha °C
160
165
170
170
175
180
S
im
43
-4
A Black-White plain paper duplex TH_UM set value
150
155
160
160
165
170
B Black-White plain paper duplex TH_LM set value
95
100
105
100
105
110
C Black-White plain paper duplex TH_US set value
150
155
160
160
165
170
E Color plain paper duplex TH_UM set value
160
165
170
170
175
180
F Color plain paper duplex TH_LM set value
95
100
105
100
105
110
G Color plain paper duplex TH_US set value
160
165
170
170
175
180
S
im
43
-2
4
X Recycled paper BW-TH_UM
155
160
165
155
160
165
Y Recycled paper BW-TH_LM
95
100
105
95
100
105
Z Recycled paper BW-TH_US
155
160
165
155
160
165
AA Recycled paper COL-TH_UM
165
170
175
165
170
175
AB Recycled paper COL-TH_LM
95
100
105
95
100
105
AC Recycled paper COL-TH_US
165
170
175
165
170
175
Lower setup Higher
Lower setup Higher
Click on the first or last page to see other MX-4110N / MX-4111N / MX-4112N / MX-4110FN / MX-4111FN / MX-5110N / MX-5111N / MX-5112N / MX-5110FN / MX-5111FN (serv.man132) service manuals if exist.