MX-4101N  FUSER SECTION  M – 4
2)
Remove the blue screw and the step screw. Release the lock
lever and remove the fusing unit.
(1) Upper thermostat
1)
Remove the fusing unit.
2)
Remove the screw. Pull out the interface harness and remove
the fusing upper cover.
3)
Remove the screw, and remove the terminal. Remove the
upper thermostat.
* Install so that the caulked section of the terminal faces up.
(2) Lower thermostat
1)
Remove the fusing unit.
2)
Remove the screw, and remove the fusing lower cover.
3)
Remove the screw, and remove the terminal. Remove the
lower thermostat.
* Install so that the caulked section of the terminal faces
down.
(3) External thermostat
1)
Remove the fusing unit.
2)
Remove the fusing upper cover.
3)
Remove the screw, and remove the terminal. Remove the
external thermostat.
* Install so that the caulked section of the terminal faces up.
2
1
1
1
3
2