MX-4101N MAINTENANCE 8 – 8
16) Remove the side seal F/R.
Maintenance: Check at every 100K (color) or every 150K
(monochrome). (Replace as necessary.)
(monochrome). (Replace as necessary.)
* When attaching, use alcohol to remove oil from the attached
surface, and fit with the reference.
17) Remove the screw, and remove the DC holding plate and the
DCH lens.
18) Remove the screws, and remove the cleaner blade.
Maintenance: Replace at every 100K (color) or every 150K
(monochrome).
(monochrome).