MX-4100N, MX-4101N, MX-5000N, MX-5001N (serv.man15). Service Manual-Section 7-Self Diag and Trouble Code - Sharp Copying Equipment Service Manual (repair manual). Page 14

Read Sharp MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man15) Service Manual online

MX-4101N  SELF DIAG AND TROUBLE CODE  7 – 14
 
F1-45
Saddle staple trouble
 
F1-47
Saddle paper transport motor trouble
 
F1-50
Main unit - Finisher combination error
 
F2-22
Discharge lamp trouble (K)
 
F2-23
Discharge lamp trouble (C)
 
F2-24
Discharge lamp trouble (M)
 
F2-25
Discharge lamp trouble (Y)
 
F2-39
Process thermistor trouble
 
F2-40
Toner density sensor trouble (BLACK)
Trouble content
Abnormality of the staple unit drive motor in the 
saddle section.
Detail
PCU
Cause
Saddle staple motor trouble.
Finisher control PWB trouble.
Home position sensor trouble.
Harness and connector connection trouble.
Check & Remedy
Use SIM3-3 to check the operation of the saddle 
staple motor.
Check connection from the control PWB to the motor.
Turn OFF/ON the power.
Replace the control PWB.
Replace the sensor.
Trouble content
Abnormality in the drive roller oscillation motor in the 
finisher saddle transport section.
Detail
PCU
Cause
Saddle paper transport motor trouble.
Finisher control PWB trouble.
Harness and connector connection trouble.
Fuse blown (24V line).
Check & Remedy
Use SIM3-3 to check the operation of the saddle 
paper transport motor.
Check connection from the control PWB to the motor.
Replace the control PWB.
Replace the sensor.
Trouble content
Detail
PCU
Cause
The finisher which is not supported by the main unit 
model is installed.
Finisher control PWB trouble.
Check & Remedy
Install a proper finisher.
Replace the finisher control PWB.
Trouble content
A trouble is detected when the discharge lamp open 
sensor is open for 1 sec after turning ON the 
discharge lamp.
Detail
PCU
Cause
Contact trouble between the discharge lamp PWB 
(K) and the PCU PWB.
Discharge lamp PWB (K) trouble.
PCU PWB trouble.
Check & Remedy
Replace the discharge lamp PWB (K).
Check the harness and the connector.
Replace the PCU PWB.
Trouble content
A trouble is detected when the discharge lamp open 
sensor is open for 1 sec after turning ON the 
discharge lamp.
Detail
PCU
Cause
Contact trouble between the discharge lamp PWB 
(C) and the PCU PWB.
Discharge lamp PWB (C) trouble.
PCU PWB trouble.
Check & Remedy
Replace the discharge lamp PWB (C).
Check the harness and the connector.
Replace the PCU PWB.
Trouble content
A trouble is detected when the discharge lamp open 
sensor is open for 1 sec after turning ON the 
discharge lamp.
Detail
PCU
Cause
Contact trouble between the discharge lamp PWB 
(M) and the PCU PWB.
Discharge lamp PWB (M) trouble.
PCU PWB trouble.
Check & Remedy
Replace the discharge lamp PWB (M).
Check the harness and the connector.
Replace the PCU PWB.
Trouble content
A trouble is detected when the discharge lamp open 
sensor is open for 1 sec after turning ON the 
discharge lamp.
Detail
PCU
Cause
Contact trouble between the discharge lamp PWB 
(Y) and the PCU PWB.
Discharge lamp PWB (Y) trouble.
PCU PWB trouble.
Check & Remedy
Replace the discharge lamp PWB (Y).
Check the harness and the connector.
Replace the PCU PWB.
Trouble content
Detail
PCU
Cause
Process thermistor trouble.
Process thermistor harness connection trouble.
PCU PWB trouble
Check & Remedy
Replace the process thermistor.
Check connection of the harness and the connector.
Replace the PCU PWB.
Trouble content
Detail
PCU
Cause
Toner density sensor output abnormality (Sample 
level 25 or less, or 231 or above)
Connection trouble of the connector and the 
harness.
Developing unit trouble. PCU PWB trouble
Check & Remedy
Replace the toner density sensor.
Check connection of the connector and the harness.
Replace the developing unit.
Replace the PCU PWB.
Page of 28
Display

Click on the first or last page to see other MX-4100N / MX-4101N / MX-5000N / MX-5001N (serv.man15) service manuals if exist.