MX-3050N, MX-3060N, MX-3070N, MX-3550N, MX-3560N, MX-3570N, MX-4050N, MX-4060N, MX-4070N (serv.man133). CCE 1666R Rom Upgrade 5 6 V5 Combined Firmware Bulletin Only - Sharp Copying Equipment Technical Bulletin (repair manual)

mx-3050n, mx-3060n, mx-3070n, mx-3550n, mx-3560n, mx-3570n, mx-4050n, mx-4060n, mx-4070n (serv.man133) technical bulletin
Model
MX-3050N MX-3060N MX-3070N MX-3550N MX-3560N MX-3570N MX-4050N MX-4060N MX-4070N (serv.man133)
Pages
7
Size
500.8 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Copying Equipment / CCE 1666R Rom Upgrade 5 6 V5 Combined Firmware Bulletin Only
File
mx-3050n-mx-3060n-mx-3070n-mx-3550n-mx-3560n-mx-35.pdf
Date

Read Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man133) Technical Bulletin online

 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
 
Date:   
 
20
th
 Dec 2016 
Model:   
 
See below 
Ref.:   
 
CCE 1666R 
Colour:   
 
White 
Page:  
 
1 of 7 
TECHNICAL BULLETIN 
 
   
 
 
 
 
 
                                                                           
ROM UPGRADE 5 ~ 6 
 
                     
        Caution for firmware upgrade: Make sure to turn off the main power once.   
 
Then turn on the power and upgrade the firmware.
 
 
- If the firmware update procedure is executed while MFP is still operating, the operation 
panel becomes black after the firmware upgrade and MFP may not be able to start up in 
some rare cases
.
 
 
- If upgrading from the version older than 04.01.Z1.00
, you won’t be able to restore original 
version. 
 
 
If "Google drive" is used with the version older than 04.01.Z1.00, it will no longer be used 
after firmware upgrade. 
In that case, go into System Settings > Cloud Connect Settings and enable "Google drive" 
for usage. 
 
1. Model Name: 
MX-3050N/3550N/4050N/5050N/6050N 
 
MX-3060N/3560N/4060N/3070N/3570N/4070N/5070N/6070N 
 
2. Description: 
Upgrade of ICU,ASIC,PCU,SCU,SPF-ROM,E-Manual  …  (6) 
From mid-November 2016 
Model 
ROM 
control No. 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
SPF 
E-Manual 
MX-3050N 
MX-3550N 
MX-4050N 
MX-5050N 
MX-6050N 
E01 
0511K100_ 
16111601 
0511K100  0510Z100  0500Z100  0400Z100 
0230K100 
MX-3060N 
MX-3560N 
MX-4060N 
0511Z100_ 
16111601 
0511Z100  0510Z100  0500Z100  0400Z100 
0230Z100 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5070N 
MX-6070N 
0400Z100 
    Item of change  :Improvement of inspection program for production process 
(Then purpose of version upgrade is to improve productivity. No change in machine 
setting since Ver0510Z100/0510K100.) 
 
 
 
 
 
 
 
 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
 
Upgrade of ICU,ASIC,PCU,SCU,SPF-ROM,E-Manual  …(5) 
From mid-November 2016 
Model 
ROM 
control No. 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
SPF 
E-Manual 
MX-3050N 
MX-3550N 
MX-4050N 
MX-5050N 
MX-6050N 
E00 
0510K100_ 
16110700 
0510K100  0510Z100  0500Z100  0400Z100 
0230K100 
MX-3060N 
MX-3560N 
MX-4060N 
0510Z100_ 
16110700 
0510Z100  0510Z100  0500Z100  0400Z100 
0230Z100 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5070N 
MX-6070N 
0400Z100 
    Item of change  :  See the separate page 
 
 
 
 
ROM Version Combination History Table 
No. 
Destination 
ROM 
Control 
No. 
Model 
BUNDLE 
ICU 
ASIC 
PCU 
SCU 
SPF 
FAX
 
E-Manual 
Action 
T/R No 
(4) 
ALL 
D01 
MX-5070N 
MX-6070N 
0401Z100_ 
16080400 
0401Z100 
0400Z100 
0401Z100 
0300Z100 
0300Z100 
0220Z100 
2016/8 
Mid 
CCE-1634
R2 
(3) 
D00 
MX-3050N 
MX-3550N 
MX-4050N 
MX-5050N 
MX-6050N 
0400K100_ 
16061400 
0101Z100 
0400Z100 
0400Z100 
0300Z100 
0220K100 
2016/6 
CCE-1605 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5070N 
MX-6070N 
0400Z100_ 
16061400 
0101Z100 
0400Z100 
0400Z100 
0300Z100 
0300Z100 
0220Z100 
(2) 
B01 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
0201Z100_ 
16011400 
0201Z100 
0201Z100 
0200Z100 
0200Z100 
0100Z10a 
0150Z100 
2016/2 
Mid 
CCE-1515 
North 
America 
MX-3050N 
MX-3550N 
MX-4050N 
0201K100_ 
16011400 
0201Z100 
0200Z100 
0200Z100 
0201K100 
0100Z100 
0130K100 
Except for 
North 
America 
A01 
(1) 
ALL 
B00 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
0200Z100_ 
15121800 
0200Z100 
0200Z100 
0200Z100 
0100Z10a 
0101Z100 
0150Z100 
2015/12 
Mid 
CCE-1507 
MX-3050N 
MX-3550N 
MX-4050N 
0200Z100_ 
15121800 
0200K100 
0200Z100 
0200Z100 
0200Z100 
0100Z100 
0130K100 
 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
 
【Description】 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
Main unit 
control 
Change in specification of account lockout 
Authentication failure was managed irrespective of user. The specification 
is changed so that authentication failure of each user can be managed. 
○ 
○ 
○ 
○ 
Main unit 
control 
Implementation of Soft SW to print A5 size paper as A5R from Bypass tray. 
When this SW is enabled, the A5 size image output from Bypass tray is 
automatically output as A5R size. 
 
SIM55-3 SW39 Data 5 
0: Disabled (Default) 
1: Enabled 
 
*Following setting has to be turned ON to enable this feature: 
System Settings > Printer Settings > Condition settings > Enable Detected 
Paper Size in Bypass Tray: ON 
○ 
○ 
○ 
○ 
Main unit 
control 
Correction of the following issues which may be caused at startup of the 
machine. 
*E7-90 trouble 
*Indication of Toner Quantity [0%] 
○ 
○ 
○ 
○ 
Main unit 
control 
Correction of failure to switch to System Settings 
When Address Book DB is corrupted, it cannot be recreated properly that 
unable to switch to System Settings. 
○ 
○ 
○ 
○ 
Main unit 
control 
Correction of operational failure: Following problem occurred when the 
MFP was used 25 five days in a row (without turning off the power) 
- A message which indicates machine is not available for usage appeared. 
- The LCD turned dark. 
○ 
○ 
○ 
○ 
Main unit 
control 
Correction of a problem Downloading E-manual for Asia fails occasionally 
○ 
○ 
○ 
○ 
Main unit 
control 
Correction of slowing down the transmission speed after sending multiple 
jobs 
○ 
○ 
○ 
○ 
Main unit 
control 
Eliminating load on SSD 
The log data are written many times under the environment where the MFP 
switches to power save mode and recover from power save mode 
frequently. The transition time from 1W power save mode -> silent recovery 
-
> power save mode has been changed from “1 min.”  to “15 min.” to 
decrease the writing of log data to reduce load on SSD. 
○ 
○ 
○ 
○ 
Main unit 
control 
Correction of failure to notify IPP authentication error to a client 
○ 
○ 
○ 
○ 
10 
Main unit 
control 
Correction of failure to change the current status of Machine Identification 
from “Input Tray Empty” 
○ 
○ 
○ 
○ 
11 
Main unit 
control 
Correction of failure to recover from power save mode 
○ 
○ 
○ 
○ 
12 
Main unit 
control 
Correction of failure to reflect the name of the registered paper type in the 
Tray Settings 
○ 
○ 
○ 
○ 
13 
Main unit 
control 
Correction of failure to execute “Save User Count” 
○ 
○ 
○ 
○ 
14 
Main unit 
control 
Correction of failure which tapping of “Contacts/Group Address” icon on 
Home screen rejected, displaying an error message “This function cannot 
be selected.”. 
○ 
○ 
○ 
○ 
○=applied 
 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
 
No. 
Item 
Description 
Model 
MX-3050N 
MX-3550N 
MX-4050N 
MX-3060N 
MX-3560N 
MX-4060N 
MX-3070N 
MX-3570N 
MX-4070N 
MX-5050N 
MX-6050N 
MX-5070N 
MX-6070N 
15 
Main unit 
control 
Correction of E7-03 error or failure to start-up MFP。 
○ 
○ 
○ 
○ 
16 
Main unit 
control 
Correction of high temperature offset on B4/B5 size paper with Plain Paper 
Weight Setting 90 g/m² - 105g g/m²(23+~28lbs
’) 
 
Plain Paper Weight Settings 
System Settings > Common Settings > Device Control 
NA 
NA 
○ 
○ 
17 
Main unit 
control 
Change of judgement conditions to execute auto cleaning for main charger 
The purpose of this change is to remedy uneven charge under low humidity 
environment 
NA 
NA 
○ 
○ 
18 
Main unit 
control 
Correction of L4-19   
The error due to toner waste buildup caused by the failure to detect waste 
toner box full has been fixed. 
○ 
○ 
○ 
○ 
19 
Main unit 
control 
Change of heater lamp control 
This is to adjust to the fluorescent which flickers during fluctuation of 
voltage. 
○ 
○ 
○ 
○ 
20 
Main unit 
control 
Remedy of overtoning and toner dispersion due to replenishment of excess 
amount of toner 
○ 
○ 
○ 
○ 
21 
Main unit 
control 
Correction of C1-01/03/05/07 trouble during MC cleaning under HH 
environment 
NA 
NA 
○ 
○ 
22 
Main unit 
control 
Correction of false detection of F2-22 (Discharge lamp trouble (K)) 
The trouble may occur while the job in monochrome mode (which tends to 
trigger the execution of process control for BK) is mainly running. 
NA 
NA 
○ 
○ 
23 
Main unit 
control 
Correction of F2-65 trouble 
This trouble may occur if the MFP is runs out of toner during continuous 
run, failing to replenish the toner properly. 
NA 
NA 
○ 
○ 
24 
Main unit 
control 
Correction of failure to recognize original 
The problem may occur if an OC cover is opened and closed too quickly 
after placing an original on the table, failing to detect original size. 
○ 
○ 
○ 
○ 
25 
Main unit 
control 
Correction of machine lockup   
The lockup may occur while scanning non standard size originals (with 235 
mm in width) on RSPF, displaying “Originals are being read”. 
○ 
○ 
○ 
○ 
26 
Printer 
Correction of the error (Size illegal) caused when printing out the long size 
paper if the setting is the printer driver preferred setting. 
○ 
○ 
○ 
○ 
27 
Printer 
Printer using AirPrint cannot be registered with Mac OS 10.10.    This has 
been supported. 
○ 
○ 
○ 
○ 
28 
Printer 
Correction of the error (Large-volume of pages is printed as text data) 
caused when printing the specific EPS file. 
○ 
○ 
○ 
○ 
29 
Printer 
Correction of the problem that the machine does not output the data with 
"Rendering" displayed in Job Status screen when printing the specific data. 
○ 
○ 
○ 
○ 
30 
Printer 
Correction of failure to print on Index paper properly 
When Index paper setting is turned on and Short Edge Duplex is set, the 
papers are bound on long edge. 
○ 
○ 
○ 
○ 
31 
Printer 
Correction of failure to register Print release 
If multiple jobs for print release are registered all at once, the jobs may not 
be registered on Print release job screen. 
○ 
○ 
○ 
○ 
32 
Printer 
Correction of failure to perform Cloud Print properly 
When 2-Sided Tablet (Booklet) and 8 up are set for Cloud Print, the job may 
not be performed properly. 
○ 
○ 
○ 
○ 
○=applied 
Page of 7
Display

Download Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man133) Technical Bulletin

Here you can read online and download Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man133) Technical Bulletin in PDF. MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man133) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man133) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.