MX-2640N, MX-2640NR, MX-2640FN, MX-3140N, MX-3140NR, MX-3140FN, MX-3640N, MX-3640NR, MX-3640FN (serv.man170). FIELD SUPPORT FOR REDUCTION OF FUSING PERFORMANCE AND WEB NOISE IN HIGH TEMPERATURE ENVIRONMENT - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man170) Technical Bulletin online

 
 
 
2/3 
 
Detail of WEB path change 
 
Narrow down the pulling angle from the nip by changing the path of WEB against the WEB tension   
 
axis.   
 
This change will enable to improve the resistant to the noise (vibration noise) which is ascribable to   
 
the WEB contamination.     
 
 
 
 
 
 
 
 
 
 
 [Work 
Procedure] 
 1) 
  Before 
change 
 
 
 
 
 
 2) 
  After 
change 
 
 
 
 
 
 
 3) 
 
 
 
 
 
 
 
 
Before change 
After change
Lower side of tension axis 
Upper side of tension axis 
  *Remove the screw x 2, and take 
  off the holder. 
  *Remove the tension axis, and then
    insert it to the underside of WEB. 
  *Install the holder. 
  Check that the tension axis is 
  placed on the underside of WEB.
  *After installing the WEB unit, 
    be sure to rotate the lever to 
    make no slack on the WEB. 
Tension axis