MX-2630 (serv.man13). CCE 1831 IMPORTANT NOTE WHEN INSTALLING OPTIONS to MX2630 and MX30XX series - Sharp Copying Equipment Technical Bulletin (repair manual). Page 2

Read Sharp MX-2630 (serv.man13) Technical Bulletin online

     
1 Attachment of HL edge protect sheet:
(1) Remove the rear cover.
(2) Remove the connector and the ground wire from the PCU PWB.(①)
     Then, open the PCU PWB fixing plate unit and the MC fixing plate unit.(②)
(3) Attach HL PWB protect sheet. 
(4) Close PCU PWB fixing plate unit and MC fixing plate unit, and install the connector and the ground wire to PCU PWB,
     and then attach the rear cover.
Interface PWB DE unit
MX-DE25 and others <=> MX-2630N, MX-M3500 series
Procedure to connect Interface PWB DE unit
Reference line (Wall 
face)
↑2mm
Reference line (End face)
←0.5mm
→0.5mm
Combination table of Interface PWB DE unit configuration parts and the service parts
No
Parts name
PN
MX-DE25
MX-DE26
MX-DE27
MX-DE28
MX-DE29
1
Interface PWB DE unit
DKIT-0473DSZZ
Required
Required
Required
Required
Required
Should be arranged
2
Interface PWB UN DE
CPWBN2307FCE1
Required
Required
Required
Required
Required
Supplied with No.1
3
Interface harness DE A
DHAI-6178FCPZ
Required
Required
Required
Required
Required
Supplied with No.1
4
Interface harness DE B
DHAI-6179FCPZ
Not required
Required
Required
Required
Not required
Supplied with No.1
5
Interface harness DE H
DHAI-6180FCPZ
Not required
Not required
Not required
Not required
Not required
Supplied with No.1
6
HL edge protect sheet Ph
PSHEZ6963FCZZ
Required
Required
Required
Required
Required
Supplied with No.1
7
M3 x 8 S-Tight
XHBS730P08000
Required
Required
Required
Required
Required
Supplied with No.1
MX-2630N, MX-M3500 series
*Combination of Service Parts
Remark
Page of 6