Read Sharp MX-2610N / MX-3110N / MX-3610N (serv.man211) Technical Bulletin online
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-918
No.
Item
Details
57
Image transfer related
When selecting a recipient for a FAX/image, "Job overflow. Input not possible." would be
displayed, preventing sending. This glitch has been corrected.
displayed, preventing sending. This glitch has been corrected.
Furthermore, when this glitch occurs, updating the firmware can apply the
countermeasures, fixing the machine. However, on a machine suffering from this glitch,
performing the normal firmware upgrade to SIM49-01 will require an abnormally long
amount of time, therefore, perform firmware upgrade using the CN update function.
countermeasures, fixing the machine. However, on a machine suffering from this glitch,
performing the normal firmware upgrade to SIM49-01 will require an abnormally long
amount of time, therefore, perform firmware upgrade using the CN update function.
58
Image transfer related
Sending to a file server using Scan to SMB is not possible. This glitch has been
corrected.
corrected.
59
OSA related
When using OSA applications, between the user name input and password input the
screen would blink. This glitch has been corrected.
screen would blink. This glitch has been corrected.
60
OSA related
When printing from OSA applications, in some cases, print settings of specified copy
count, etc. would not be reflected in the incorrect print results. This glitch has been
corrected.
count, etc. would not be reflected in the incorrect print results. This glitch has been
corrected.
61
Software SW related
To improve transmission performance, the send packet size has been increased from 3
KB to 16 KB. However, depending on the network settings there are cases where an
error would occur. Therefore, the packet size can be changed in the software SW.
KB to 16 KB. However, depending on the network settings there are cases where an
error would occur. Therefore, the packet size can be changed in the software SW.
Controller software SW (Sim55-3)
SW No. 31 Data 1
0: 16 KB (default)
1: 3KB
62
Software SW related
The polygon motor control of the LSU has been changed. A reduced motor sound mode
has been added to the software SW. Furthermore, if quiet mode is enabled, after a print
job is completed, restarting for the next print job will start slightly later.
has been added to the software SW. Furthermore, if quiet mode is enabled, after a print
job is completed, restarting for the next print job will start slightly later.
Engine control SW (Sim55-1)
SW No. 1 Data 4
0: Normal (default)
1: Quiet mode
63
FSS related
Enabling FSS (HTTP polling) would, in some cases, not cause the machine to recover
from 1 W power saving mode. This glitch has been corrected.
from 1 W power saving mode. This glitch has been corrected.
64
USB related
An MFP machine and a PC connected via USB would not recover from power saving
mode. This glitch has been corrected.
mode. This glitch has been corrected.
65
Simulation related
The version display digits of the Sim22-05 "ROM version display" has been changed from
6 to 8. The Build No. (Development Administrative Number) will now be displayed.
6 to 8. The Build No. (Development Administrative Number) will now be displayed.
[Example]
02.00.A1.00
Build No.
Click on the first or last page to see other MX-2610N / MX-3110N / MX-3610N (serv.man211) service manuals if exist.