MX-2610N, MX-3110N, MX-3610N (serv.man181). MX-FR30U FIRMWARE DSK ONLY MX2610N-MX3110N-MX3610N Combined MFP Firmware Version 06.00.A1(Bulletin Only) - Sharp Copying Equipment Technical Bulletin (repair manual). Page 4

Read Sharp MX-2610N / MX-3110N / MX-3610N (serv.man181) Technical Bulletin online

 
                                                                                                                                    
CCE-1018R  
 
 
 
the IC card was authenticated, in some cases, the card ID was recorded in the job 
log even though it was the manual input.  This problem has been corrected.   
29 
 
Main unit 
Authentication 
With the setting of IC card or the manual log-in by the manual input, using the 
LDAP Authentication, if you attempted the manual log-in by the manual input when 
LDAP server was down, in some cases, the "Authentication is succeeded" 
message would be displayed even though it was the manual input.  This problem 
has been corrected.   
30 
Main unit 
Authentication 
With the setting of IC card or the manual log-in by the manual input, using the 
LDAP Authentication, if you attempted the manual log-in by the manual input, in 
some cases, it would fail.  This problem has been corrected.   
No. Item 
Details 
31 Web 
Page 
When the "Sys Log" in the Service Web Page was set to "Enable", in some cases, 
the U2 error was caused by the execution of Reboot from the Web Page.  This 
problem has been corrected.   
32 Trouble 
Code 
The U2 trouble that should not have been cleared unless SIM16 was executed 
could be cleared by the power-OFF/ON.  This problem has been corrected.  
 
(If the corrective firmware for this issue is installed to the machine that U2 trouble 
was cleared only by the power-OFF/ON, the U2 trouble will be displayed when the 
machine is turned ON after the completion of the installation so the appropriate 
process to clear the U2 trouble will be required.)  
33 Trouble 
Clear 
For the POD1_N jam, the modification has been made not to clear the jam unless 
you open the right door.  (Jam cannot be cleared by the power-OFF/ON) 
34 E-mail 
RIC 
At the timing of sending the Alert Mail of E-mail RIC, the mode to prevent more 
than one Alert Mails of the same event from being sent out when warming up from 
the Energy Save has been added to the controller Soft SW.   
 
SIM55-3  SW No. 28  Data 3 
  0: Allowed: Current operation (Default) 
  1: Not Allowed  
35 Option 
When using OSA application, the output trays which should be unable to use were 
selectable.  This problem has been corrected.  
Page of 4
Display

Download Sharp MX-2610N / MX-3110N / MX-3610N (serv.man181) Technical Bulletin