MX-2610N, MX-3110N, MX-3610N (serv.man170). MX-FR30U FIRMWARE DSK ONLY MX2610N-MX3110N-MX3610N Combined MFP Firmware Version 07.00.AC(Bulletin Only) - Sharp Copying Equipment Technical Bulletin (repair manual)

mx-2610n, mx-3110n, mx-3610n (serv.man170) technical bulletin
Model
MX-2610N MX-3110N MX-3610N (serv.man170)
Pages
3 Few pages! See other manuals at the bottom of the first or last page.
Size
25.76 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Copying Equipment / MX-FR30U FIRMWARE DSK ONLY MX2610N-MX3110N-MX3610N Combined MFP Firmware Version 07.00.AC(Bulletin Only)
File
mx-2610n-mx-3110n-mx-3610n-sm170.pdf
Date

Read Sharp MX-2610N / MX-3110N / MX-3610N (serv.man170) Technical Bulletin online

 
                                                                                                                                       
CCE-1040   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
                                                                                                                                                                                                         
                                                                                                                                                                                                         
                                                                                                                                                                                                       
1. Model Name        
MX-FR30U(Options for MX-2610N/3110N/3610N) 
 
2. Description
 
Upgrade of ICU-ROM 
 
From July 2012 production 
ROM control No. 
ICU 
H00 0700Ac 
 * ICU above is the version described in the ROM management label.  Check that the actual 
  version is: ICU(MAIN): 07.00.Ac.00/ICU(BOOT): 01.00.Ac.00/LANGUAGE: 01.59.A1.00/ 
  GRAPHIC: 01.00.A1.00/UICONTENTS: 07.00.Ac.00/PCL(MAIN): 07.00.A1.00; by Sim22-5.  
  Item of change: See the attached sheet 
 Note) This report is a T/R for the data security kit option, corresponding to general 
       T/R No. CCE-1036 
 
 
 
 
          ROM Version History Table 
 
No. 
ROM control No. 
ICU Action T/R 
No. 
(6) G00  0600Ac 
2012/4 
CCE-1018 
(5) F00  0500Ac 
2012/2 
CCE-1001 
(4) E00  0400Ac 
2011/11 
CCE-976 
(3) D00  0300Ac 
2011/9 
CCE-953 
(2) C00  0200Ac 
2011/7 
CCE-935 
(1) B00  0110Ac 
2011/4 
CCE-903 
 
 
ROM UPGRADE ..... (7). 
TECHNICAL BULLETIN 
Date: 12
th
 July 2012 
Model: MX-FR30U 
Ref: CCE-1040  
 
Colour: White 
 
Page: 1  OF  3 
 
                                                                                                                                       
CCE-1040   
 
 
 
[Description] 
No. Item 
Details 
1 UI 
In some cases, the icon on the Home screen was not displayed.  This problem has 
been corrected.  
2 UI 
Even though the "Disable Registration of Program" was selected in System 
Settings, the user program could be deleted.  This problem has been corrected.  
(Modification has been made to prohibit the deletion of the program and the 
change of the program name when the "Disable Registration of Program" is 
selected.)   
3 UI 
When authenticating the user, if the operation was locked due to entering the 
wrong password three times, it was not unlocked even over 5 minutes passage 
after the power switch on the panel was turned OFF/ON.  This problem has been 
corrected. 
4 UI 
When the default was set to the Copy screen and the user authentication was 
enabled, if the Toner Empty occurred, the message "Change the toner cartridge" 
without the [OK] button would be displayed, and the authentication password 
could not be input.  This problem has been corrected.  <Modification has been 
made to display the message "Change the toner cartridge" with the [OK] button 
when the authentication is enabled (before log-in)>. 
5 UI 
When using MFP for a long time without entering the 1W Energy Save mode, in 
some cases, the operation panel became unresponsive.  This problem has been 
corrected. 
6 UI 
The message when entering the password for the encrypted PDF has been 
changed.  
 
[Before the change] 
Enter the password? 
[Yes] [No] 
 
[After the change] 
Please enter Password. 
[Cancel] [OK] 
Authentication 
Control 
When the user name could not be taken from LDAP with the network 
authentication, the first 16- character of the log-in name used for the network 
authentication was previously used.  Now the modification has been made to use 
the log-in name directly without cutting off at the first 16-character. 
Authentication 
Control 
When registering the IC Card on User List in System Settings, if the IC card was 
set to the card reader before the operation of the card registration was performed, 
the IC Card could not be registered.   
This problem has been corrected. 
Authentication 
Control 
When the log-in user did not conduct the appropriate log-out processing and left 
the machine with the error like Cover Open displayed on the operation panel, the 
next user could not log in.  This problem has been corrected.  
10 Copier 
Modification has been made to store also the paper size for the bypass tray on 
Copy Job Program. 
11 Copier 
When turning OFF/ON the machine after the custom paper size was registered as 
the Inch-size, the data would be printed only in the smaller area than the area of 
the registered size.  This problem has been corrected. 
12 Printer 
With the user authentication, the log-in name which would be recorded to the job 
log when the invalid user executes the print job under the condition that the 
invalid user is able to print ("Disable Printing by Invalid User" is OFF) has been 
changed as below: 
 
[Before the change] 
User Unknown/ PC Login Name 
 
[After the change] 
 
                                                                                                                                       
CCE-1040   
 
 
 
User Name specified on the driver/ Login Name specified on the driver 
13 Printer 
When printing the special data that the specification of the number of download 
font was 65535, the PCL XL error occurred.  This problem has been corrected. 
14 Network 
When using "Scan to Network Folder", if the Network Folder was specified not 
with the IP address but with the server name (15 characters for the hostname), in 
some cases, the machine hanged up and could not send the data.  This problem 
has been corrected. 
 
No. Item 
Details 
15 Network 
There were some cases where Scan to E-Mail failed under the network 
environment that a large amount of ARP packets were running.  This problem has 
been corrected. 
16 Network 
17 Network 
When editing the address from the Web Page of the machine, it was slow to 
display the certain address. 
This problem has been corrected. 
18 Network 
When scanning with OSA, if the application server was Microsoft-IIS/Ver.7.0 or 
later version, the communication error occurred during the data sending by HTTP.  
This problem has been corrected. 
19 Sharp 
Desk 
Mobile 
Modification has been made not to display the registration confirmation message 
on the operation panel of the main unit when registering the profile with Scan 
function of Sharp Desk Mobile. 
20 Image 
Send 
There were some cases where the Fax reception memory did not return to 100%.  
This problem has been corrected. 
21 Other 
As the further improvement of the issue that it took some time to browse the data 
in the NAS folder when using NAS function of the machine, the SMB protocol 
control and file access control have been more improved. 
 
22 Other 
When the "Tray Auto Switch" setting is OFF, the fusing cleaning page would be 
output as the blank page.  This problem has been corrected.  
23 Other 
In the environment where more than 1,000 users log on to one MFP with the 
authentication like schools, in some cases, the U2 error message would appear 
even though the U2 error did not occur.  This problem has been corrected.  
24 Other 
Modification has been made to change the frequency to obtain the information of 
the remaining toner using MIB with SOFT SW (SIM55-3).   
 
 SW No. 32  Data 2 
  0: every 25% (Default) 
  1: every 5% 
 
 
 
 
 
 
 
Page of 3
Display

Download Sharp MX-2610N / MX-3110N / MX-3610N (serv.man170) Technical Bulletin

Here you can read online and download Sharp MX-2610N / MX-3110N / MX-3610N (serv.man170) Technical Bulletin in PDF. MX-2610N / MX-3110N / MX-3610N (serv.man170) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp MX-2610N / MX-3110N / MX-3610N (serv.man170) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.