Read Sharp MX-2600N / MX-3100N / MX-2600G / MX-3100G (serv.man76) Technical Bulletin online
Date:
20
th
January 2010
Model:
MX2600N – MX3100N
Ref.:
042
Colour:
White
Page:
1 of 2
TECHNICAL BULLETIN
ROM UPGRADE ..... (8).
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-739
1. Model Name:
MX2600N – MX3100N
2. Description:
Upgrade of ICU-ROM
From November 2009 production
ROM
control No.
ICU PCU SCU
IMAGE
DATA
FAX E-Manual
E00 0400P2 0104P2 0102P2 0102P2 0102P2 0140P2
* ICU above is the version described in the ROM management label. Check that the actual
version is:
ICU(MAIN): 04.00.P2/ICU(BOOT): 01.01.P2/LANGUAGE: 01.23.P2/
GRAPHIC: 01.04.P2/COLOR_PROFILE: 01.01.P2 (Sim22-5).
Note: After upgrading, enable copy colour balance adjustment (automatic adjustment)/
print colour balance adjustment (automatic adjustment) in Sim46-74.
Item of change: See the accompanying sheet.
ROM Version Combination History Table
No.
ROM
administration
ICU PCU SCU
IMAGE
DATA
FAX E-Manual Action
(7)
D01
0301P2 0104P2 0102P2 0102P2 0102P2 0140P2
2009/7Mid
(6)
D00
0300P2 0104P2 0102P2 0102P2 0102P2 0140P2
2009/7
(5)
C00
0210P2 0103P2 0101P2 0101P2 0102P2 0130P2
2009/2Mid
(4)
B02
0104P2 0102P2 0100P2 0100P2 0100P2 0120P2 2008/11Mid
(3)
B01
0103P2 0101P2 0100P2 0100P2 0100P2 0120P2 2008/10Mid
(2)
B00
0102P2 0101P2 0100P2 0100P2 0100P2 0120P2
2008/8Mid
(1)
A21
0101P2 0100P2 0100P2 0100P2 0100P2 0111P2
2008/6Mid
[Description]
No. Subject
Description
1 OSA3.5
support
Support for OSA3.5 has been added.
2
Software switch-
related
related
The following settings have been added to the FAX software SW.
- SW66-1: When receiving from the internet FAX, the size is selectable.
1: Complies with SW66-5
0: Complies with SW62-4, 5 (default)
- SW66-5: When receiving from the internet FAX, B4 size is selectable.
1: Do no select B4
0: Select B4 (default)
* When you want to print a received I-FAX to only B4, use the following settings in FAX
software SW.
SW66-1: [1]
SW66-5: [0]
When you want to switch conventional paper selection switch (through SW62-4, 5) when
printing a received I-Fax, use the following setting in FAX software SW.
printing a received I-Fax, use the following setting in FAX software SW.
SW66-1: [0]
Or,
SW66-1: [1]
SW66-5: [1]
3 Printer-related
By printing from the GDI with “Heavy paper 1” set for paper type, double-sided printing
was not possible. This glitch has been corrected.
was not possible. This glitch has been corrected.
4 Printer-related
Data after the EOI (End of Image) marker in JPEG data of the pasted image may not be
printed because a PCL-XL error occurs as incorrect data. This glitch has been corrected
so that data after the EOI marker is ignored.
printed because a PCL-XL error occurs as incorrect data. This glitch has been corrected
so that data after the EOI marker is ignored.
5 Printer-related
When outputting data with images in QuarkXPress, parts of the image would be corrupted
and lines would be erased upon printing. This glitch has been corrected.
and lines would be erased upon printing. This glitch has been corrected.
6 Printer-related
When printing directly from USB and the insufficient memory error was displayed, the
Notice Page text was incorrect. This has been corrected.
Notice Page text was incorrect. This has been corrected.
[Before correction]
A field in the TIFF file is not supported. The print job has been cancelled.
[After correction]
There is insufficient memory. Printing has been interrupted.
7 Printer-related
When printing documents with both horizontal and vertical data from the PCL5 in a non-
Windows environment, the horizontal data would not be printed in the correct direction.
This glitch has been corrected.
Windows environment, the horizontal data would not be printed in the correct direction.
This glitch has been corrected.
8 Printer-related
When using a print macro of the PCL5, characters and images would not output in the
specified colour. This glitch has been corrected.
specified colour. This glitch has been corrected.
9 Printer-related
Regarding the USTATUS DEVICE command (server-side), there have been cases where
the MFP does not send the correct command and, as a result, the same data would be re-
printed. This glitch has been corrected.
the MFP does not send the correct command and, as a result, the same data would be re-
printed. This glitch has been corrected.
10 Printer-related
If a page with a large amount of characters was printed through PCL5, the print speed
would become slower based on the number of characters printed. This glitch has been
corrected.
would become slower based on the number of characters printed. This glitch has been
corrected.
11 OSA
related
Regarding OSA external authentication, when the server load is too high, an
authentication error occurs and the print job cannot be completed. This glitch has been
corrected.
authentication error occurs and the print job cannot be completed. This glitch has been
corrected.
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-739
No. Subject
Description
12 OSA
related
13 OSA
related
When connecting a keyboard, while in an OSA application, the frame display of the focus
would go out of alignment or remain on-screen. This glitch has been corrected.
would go out of alignment or remain on-screen. This glitch has been corrected.
14 OSA
related
When typing into a text box from a connected USB keyboard in an OSA application and
power-saving mode was entered and then recovered from, the text that was entered
would not be displayed on the screen or the main unit would freeze, in some cases. This
glitch has been corrected.
power-saving mode was entered and then recovered from, the text that was entered
would not be displayed on the screen or the main unit would freeze, in some cases. This
glitch has been corrected.
15 OSA
related
From the main unit operations, when [OSA]
[Job Status]
[OSA] operations were
performed, the screen before and after the Job Status screen would not be the same (the
screen status would be re-initialized). This glitch has been corrected.
screen status would be re-initialized). This glitch has been corrected.
16 OSA
related
In an OSA application, the job completion notice would not be output. This glitch has been
corrected.
corrected.
17 UI-related
While tray automatic selection is set to disabled, if paper runs out during printing and the
replacement paper was set to the correct paper, a message prompting that the paper
selected is incorrect would be output. This glitch has been corrected.
replacement paper was set to the correct paper, a message prompting that the paper
selected is incorrect would be output. This glitch has been corrected.
18 UI-related
For Italian and French, there was one part of the operation panel that was localized
incorrectly. This error has been corrected.
incorrectly. This error has been corrected.
19 Webpage
related
When attempting to download the ICC Profile from the Service Web Page, the download
could not be completed due to insufficient capacity. This glitch has been corrected.
could not be completed due to insufficient capacity. This glitch has been corrected.
20 Webpage
related
If the image display operation for document filing data, from the Web screen, is repeatedly
operated, the web page would not display “Downloading image”, instead, the main unit
would freeze. This glitch has been corrected.
operated, the web page would not display “Downloading image”, instead, the main unit
would freeze. This glitch has been corrected.
21 Copy
related
When the number of pages is specified in [Special Functions]
[Print Menu] of Copy,
the printed page's character size will vary depending on the number of lines printed. This
glitch has been corrected.
glitch has been corrected.
22 Option
related
On the built-in keyboard model, if a keyboard type card reader is connected to the read
USB port and low-power mode is entered and then recovered from, the Keyboard type
card reader will not be recognized. This glitch has been corrected.
USB port and low-power mode is entered and then recovered from, the Keyboard type
card reader will not be recognized. This glitch has been corrected.
23
Firmware upgrade
related
related
If an MX-2301FN is incorrectly updated with the firmware for the MX-2600 series/3100
series, an “E7-60” error would occur and recovery of the firmware with Sim49-01 was not
possible. Depending on the CN update, support is required. However, recovery by
reloading the firmware with Sim49-01 has been made possible.
series, an “E7-60” error would occur and recovery of the firmware with Sim49-01 was not
possible. Depending on the CN update, support is required. However, recovery by
reloading the firmware with Sim49-01 has been made possible.
24
E-mail RIC related
Toner counter and remaining toner items have been added to the E-mail RIC main text.
25 Other
When the network connection speed is slow, the remote operation panel will become
abnormally slow. The following has been performed to improve this functionality.
abnormally slow. The following has been performed to improve this functionality.
1) The compression option for VNC protocol has been enabled.
2) When the next data transmission request is sent while a request is being processed,
all but the final is destroyed and the drawing data is thinned.
26 Other
Of counter information displayed in the MFP main body, items that do not exist in MIB
information have been added to MIB information.
information have been added to MIB information.
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-739