MX-2600N, MX-3100N, MX-2600G, MX-3100G (serv.man3). Revised Handy Guide Version 5 July 2010 - Sharp Copying Equipment Handy Guide. Page 28

Read Sharp MX-2600N / MX-3100N / MX-2600G / MX-3100G (serv.man3) Handy Guide online

 
 
 
 
 
28 
Document Solutions After Sales Service 
 
Firmware Recovery Procedure
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2.  
Using a PC, copy the firmware file onto the root directory of the USB Memory Stick 
 
 
In the event of a power failure during a firmware update or HDD failure, the machine may fail to reboot 
because of corrupted firmware. To re‐install the firmware, it is necessary to boot the machine using a USB 
Memory Stick 
 
Firmware Recovery Procedure: 
 
 
 
1.  
Power off the Machine  
 
 
3. 
 
Rename the firmware file to 
emupdate_P2.sfu  
Example shown: 0100P20 firmware.sfu renamed to emupdate.sfu  
 
4.  
Insert the USB memory device into the machine and Power On 
 
The machine will
 BOOT
 via the USB memory device. The firmware installs automatically from 
the detected USB Memory Stick  
 
5.  
Once the firmware update has been installed successfully, power off the machine and remove 
the USB Memory Stick 
 
 
Emergency Firmware Recovery Complete 
 
 
Note: 
   
Always rename the firmware to the original SFU name i.e. 0100P20 firmware.sfu 
   
Page of 47
Display