Document Solutions After Sales Service
Firmware Recovery Procedure
2.
Using a PC, copy the firmware file onto the root directory of the USB Memory Stick
In the event of a power failure during a firmware update or HDD failure, the machine may fail to reboot
because of corrupted firmware. To re‐install the firmware, it is necessary to boot the machine using a USB
Memory Stick
Firmware Recovery Procedure:
1.
Power off the Machine
3.
Rename the firmware file to
emupdate_P2.sfu
Example shown: 0100P20 firmware.sfu renamed to emupdate.sfu
4.
Insert the USB memory device into the machine and Power On
The machine will
BOOT
via the USB memory device. The firmware installs automatically from
the detected USB Memory Stick
5.
Once the firmware update has been installed successfully, power off the machine and remove
the USB Memory Stick
the USB Memory Stick
Emergency Firmware Recovery Complete
Note:
Always rename the firmware to the original SFU name i.e. 0100P20 firmware.sfu