Read Sharp MX-2310U / MX-3111U (serv.man162) Technical Bulletin online
Sharp Electronics (UK) Ltd., Technical Services Group
CCE-965
Note: When to make the setup change, change the entire items on the Setup Details column for Sim43-1
and 43-4 as listed on the table below, not individually make a change on the item.
[Setup Details]
- MX-2310U Fusing Temperature Setup Point (Group C)
SW-A
SW-B
Ite
m
s
Setup Details
Set within the range for each
item.
Do not set outside this range.
item.
Do not set outside this range.
Set within the range for each
item.
Do not set outside this range.
item.
Do not set outside this range.
(1) (2)
Fac
tor
y def
aul
t
val
ue
(3) (4)
(1) (2)
Fac
tor
y def
aul
t
val
ue
(3) (4)
MX
-2310U
(G
roup C
)
S
im
43
-1
A Ready standby TH_UM set value
100 105 110 115 120 115 120 125 130 135
B Ready standby TH_LM set value
100 100 105 110 115 110 110 115 120 125
C Ready standby TH_US set value
130 135 140 145 150 140 145 150 155 160
D Black-White plain paper TH_UM set value
125 130 135 140 145 135 140 145 150 155
E Black-White plain paper TH_LM set value
110 110 115 120 120 120 120 125 130 130
F Black-White plain paper TH_US set value
130 135 140 145 150 140 145 150 155 160
G Color plain paper TH_UM set value
125 130 135 140 145 135 140 145 150 155
H Color plain paper TH_LM set value
110 110 115 120 120 120 120 125 130 130
I Color plain paper TH_US set value
130 135 140 145 150 140 145 150 155 160
Y Preheating TH_UM set value
90
95 100 105 110 90
95 100 105 110
Z Preheating TH_US set value
120 125 130 135 140 120 125 130 135 140
AB Preheating TH_LM set value
80
85
90
95 100 80
85
90
95 100
AF TH_UM set value when Warm-Up at 120°C or below
135 140 145 150 155 135 140 145 150 155
AG TH_LM set value when Warm-Up at 120°C or below
95 100 105 110 115 105 110 115 120 125
AH TH_US set value when Warm-Up at 120°C or below
125 130 135 140 145 135 140 145 150 155
AJ TH_UM set value when Warm-Up at 120°C or above
135 140 145 150 155 135 140 145 150 155
AK TH_LM set value when Warm-Up at 120°C or above
95 100 105 110 115 105 110 115 120 125
AL TH_US set value when Warm-Up at 120°C or above
125 130 135 140 145 135 140 145 150 155
AP
Job enable TH_UM temperature when Warm-Up at
alpha °C or above
135 140 145 150 155 135 140 145 150 155
AR
Job enable TH_UM temperature when Warm-Up at
alpha °C or below
135 140 145 150 155 135 140 145 150 155
AT
Job enable temperature (B/W) when the upper roller
temperature is lower than alpha °C
135 140 145 150 155 135 140 145 150 155
S
im
43
-4
A Black-White plain paper duplex TH_UM set value
125 130 135 140 145 135 140 145 150 155
B Black-White plain paper duplex TH_LM set value
110 110 115 120 120 120 120 125 130 130
C Black-White plain paper duplex TH_US set value
130 135 140 145 150 145 150 155 160 165
E Color plain paper duplex TH_UM set value
125 130 135 140 145 140 145 150 155 160
F Color plain paper duplex TH_LM set value
110 110 115 120 120 120 120 125 130 130
G Color plain paper duplex TH_US set value
130 135 140 145 150 145 150 155 160 165