MX-2300N, MX-2700N, MX-2300G, MX-2700G, MX-2300FG, MX-2700FG (serv.man143). 016-IMPROVEMENT OF PRIMARY TRANSFER BELT CLEANING - Sharp Copying Equipment Technical Bulletin (repair manual). Page 9

Read Sharp MX-2300N / MX-2700N / MX-2300G / MX-2700G / MX-2300FG / MX-2700FG (serv.man143) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
CCE-339
[Applying titanium hydroxide]
1. Apply titanium hydroxide to the belt.
Apply titanium hydroxide to the belt 40 times  (10 times in latitudinal direction x 4 times in longitudinal direction)
for 4 faces (making two circuits of the belt).
*Repeat half-around application and half-around rotation each 4 times.
2.
Demount the CL roller or check that the CL roller is cleared.
3.
Mount the primary transfer UN on the machine and execute simulation 25-1 (3-minute belt idling) once.
4.
Check omissions in characters, and if many omissions are found, execute simulation 25-1 once again.
5. 
If titanium hydroxide flies apart near the resist roller, clean it.
Page of 10
Display

Click on the first or last page to see other MX-2300N / MX-2700N / MX-2300G / MX-2700G / MX-2300FG / MX-2700FG (serv.man143) service manuals if exist.