MX-1800N (serv.man22). Details of each Section - B Operation Panel Section. - Sharp Copying Equipment Service Manual (repair manual). Page 2

Read Sharp MX-1800N (serv.man22) Service Manual online

MX-1800N  OPERATION PANEL  B – 2
2. Operational descriptions
A. Outline
The operation panel unit is composed of the MFP OPE-P PWB, the
LCD INV PWB/LVDS PWB, the LCD unit, and the operation keys,
and is used to operate the machine and to set and display the
machine status.
The MFP OPE-P PWB is connected to the document detection light
receiving PWB for detecting the document size. It receives light
from the document detection light emitting PWB attached to the
rear frame, detecting the document size.
The power switch of the operation panel supplies the ON/OFF con-
trol signal of the DC power source.
3. Disassembly and assembly
A. Operation panel section
(1) Operation panel unit
1)
Remove the paper exit cover and the upper cabinet left.
2)
Remove the front cabinet upper and the operation panel base
plate.
3)
Remove each cables and the grounding sheet.
4)
Remove the operation panel unit.
a. LCD INV PWB /
b. LVDS PWB
1)
Remove the operation panel unit.
2)
Remove the LCD INV PWB (A). Remove the LVDS PWB (B).
Signal
Name
Function/Operation
OCSW
Original cover SW
Timing switch for document size detection
PWRSW
Operaton panel power supply switch
Outputs the DC power supply ON/OFF control signal.
No.
Name
Function/Operation
1
MFP OPE-P PWB
Detects the key pressed on the operation panel.
2
LCD INV PWB/LVDS PWB
Drives LCD and the backlight, and controls the touch-panel.
3
Document detection light receiving PWB
Receives the light from the document detection light emitting PWB, and detects the document size.
4
Document detection light emitting PWB
Emits light for document size detection.
Unit
Parts
(1)
Operation panel unit
a
LCD INV PWB
b
LVDS PWB
c
LCD module
d
Touch panel
e
POWER SW PWB
f
MFP OPE-P PWB
(1)-e
(1)-f
(1)-a
(1)-d
(1)-c
(1)-b
(1)
B
A
Page of 3
Display

Click on the first or last page to see other MX-1800N (serv.man22) service manuals if exist.