Read Sharp DX-C310 / DX-C311 / DX-C400 / DX-C401 (serv.man80) Technical Bulletin online
CCE 700
Sharp Electronics (UK) Ltd., Technical Services Group
[Description]
No. Subject
Description
(5) -1
Main body control-
related
related
The toner motor may not be driven even if SIM10-1 (toner motor operation check) is
implemented (only when a developer tank is detected as a new product). This glitch
has been corrected.
implemented (only when a developer tank is detected as a new product). This glitch
has been corrected.
(5) -2
E-Manual-related
An incorrect value was found in the auto power shutoff setting modified in the E-
Manual version "0150F1" for MX-C380 for Europe. This value has been corrected.
(For details, see Pages "6-20" and "6-56" of E-Manual System Settings.)
Manual version "0150F1" for MX-C380 for Europe. This value has been corrected.
(For details, see Pages "6-20" and "6-56" of E-Manual System Settings.)
(4) -1
Support for new
standards of the
International
Energy Star
program
standards of the
International
Energy Star
program
The criteria change of the International Energy Star program involves the following
changes:
(1) In the destination setting (Sim26-6), the factory default values for the function of
changes:
(1) In the destination setting (Sim26-6), the factory default values for the function of
preheating and auto power shutoff have been changed.
Model name
Destination
Before After
Preheatin
g
Auto power
shutoff
Preheatin
g
Auto power
shutoff
MX-C310 Series
North America/
Europe/Australi
a
a
10min. 45min. 1min. 10min.
DX-C310 Series
North America/
Europe
10min. 45min. 1min. 10min.
MX-C380 Series
Europe/Australi
a
a
10min. 45min. 1min. 45min.
DX-C380 Series
Europe
10min. 45min. 1min. 45min.
MX-C400 Series
North
America
10min. 45min. 1min. 45min.
MX-C400 Series
North
America
10min. 45min. 1min. 45min.
(2) A change has been made so that FAN rotation is continued for a predetermined
time even after switching to power shutoff.
[Notes]
Updating to this version does not involve any change of the setting value for the
MFP printer.
MFP printer.
The time required for the function of preheating and auto power shutoff to be
active will be reset to the factory default value as described above; when a
system administrator performs the operation of saving and/or calling system
settings and then resets to the factory default value, or when "destination
change (Sim26-6)" is implemented.
active will be reset to the factory default value as described above; when a
system administrator performs the operation of saving and/or calling system
settings and then resets to the factory default value, or when "destination
change (Sim26-6)" is implemented.
(4) -2
Main body control-
related
related
If the mounted USB memory is pulled out during restarting after simulation with
restart function is released, LCD screen display may become unstable depending
on the timing. This glitch has been corrected.
restart function is released, LCD screen display may become unstable depending
on the timing. This glitch has been corrected.
(4) -3
Main body control-
related
related
A change has been made so that even if the toner cartridge is not installed, the
automatic developing adjustment sequence is executed and the toner cartridge
uninstalled message is displayed after developing adjustment end.
automatic developing adjustment sequence is executed and the toner cartridge
uninstalled message is displayed after developing adjustment end.
Click on the first or last page to see other DX-C310 / DX-C311 / DX-C400 / DX-C401 (serv.man80) service manuals if exist.