DX-C310, DX-C311, DX-C400, DX-C401 (serv.man40). COUNTERMEASURE FOR L4-16 TROUBLE DUE TO MALFUNCTION OF PRESSURE RELEASE DETECT ACTUATOR - Sharp Copying Equipment Technical Bulletin (repair manual)

dx-c310, dx-c311, dx-c400, dx-c401 (serv.man40) technical bulletin
Model
DX-C310 DX-C311 DX-C400 DX-C401 (serv.man40)
Pages
2 Few pages! See other manuals at the bottom of the first or last page.
Size
43.46 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Copying Equipment / COUNTERMEASURE FOR L4-16 TROUBLE DUE TO MALFUNCTION OF PRESSURE RELEASE DETECT ACTUATOR
File
dx-c310-dx-c311-dx-c400-dx-c401-sm40.pdf
Date

Read Sharp DX-C310 / DX-C311 / DX-C400 / DX-C401 (serv.man40) Technical Bulletin online

 
 
 
 
 
 
No.    : CCE-1124 
Date : Mar. 5, 2013 
 
 
 
Document Systems Division 
1/2 
SHARP CORPORATION 
TECHNICAL BULLETIN 
COUNTERMEASURE FOR "L4-16" TROUBLE 
DUE TO MALFUNCTION OF PRESSURE 
RELEASE DETECT ACTUATOR 
 
1. Model Name: 
MX-C310/C311/C312/C380/C381/C400/C401, DX-C310/C311/C400/C401 
 
 
MX-C380P/C400P, MX-C382SC/C402SC, MX-B381/B401, MX-B380P/B400P 
 
 
MX-C31FU/C31FU1/C32FU/C32FU1 
 
2. Symptom:   
The malfunction is caused by the mounting hole of Pressure release detect actuator of   
 
 
fusing unit being shrank due to the influence of the heat etc, which may result in "L4-16"   
 
 
trouble. 
 
3. Description: 
As the countermeasure for the malfunction because of the shrinkage of mounting hole of   
 
 
Pressure release detect actuator, the diameter of the mounting hole of Pressure release   
 
 
detect actuator has been changed from φ5 to φ5.05. 
 
 
 
- Pressure release detect actuator 
 
 
 
 
 
 
 
 
 
 
 
 
  Before change: φ5.0 
  After change:    φ5.05 
"A4" is engraved on modified parts. 
 
 
 
 
2/2 
4. Action: 
 
From February 2013 production   
 
5. Parts Action: 
Ref. 
No. 
Model 
name 
Version  P/G No. 
Current parts 
New parts 
Price 
rank 
Q'ty 
Parts name 
Effective 
time 
Inter- 
change- 
ability 
Parts code 
Parts code 
MX-C310 
MX-C311 
MX-C312 
MX-C380 
MX-C381 
MX-C400 
MX-C401 
DX-C310 
DX-C311 
DX-C400 
DX-C401 
MX-C380P 
MX-C400P 
MX-B380P 
MX-B400P 
MX-C382SC 
MX-C402SC 
MX-B381 
MX-B401 
ALL 
18-16 
16-16 
25-16 
19-16 
MLEVP1112FCA3  MLEVP1112FCA4  AN 
Pressure release 
detect actuator 
2013/2 
<Interchange> 
1. Interchangeable. 
4. Not interchangeable. 
2. Current type can be used in place of new type. 
New type cannot be used in place of current type. 
5. Interchangeable if replaced with same types of   
related parts in use. 
3. Current type cannot be used in place of new type. 
New type can be used in place of current type. 
6. Others. 
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with 
specified ones for maintaining the safety and performance of the set. 
 
Page of 2
Display

Download Sharp DX-C310 / DX-C311 / DX-C400 / DX-C401 (serv.man40) Technical Bulletin

Here you can read online and download Sharp DX-C310 / DX-C311 / DX-C400 / DX-C401 (serv.man40) Technical Bulletin in PDF. DX-C310 / DX-C311 / DX-C400 / DX-C401 (serv.man40) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp DX-C310 / DX-C311 / DX-C400 / DX-C401 (serv.man40) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.