2. Installation
Parts included
Turn off the main switch of the copier and then remove the power plug
of the copier from the outlet.
1. Remove the platen cover.
Lift the platen cover and remove it from the copier.
2. Remove the screws of the glass holders.
Remove the two screws (M3 x 8) of the left glass holder and the three
screws (M3 x 8) of the right glass holder.
3. Remove the front cabinet.
While raising the front cabinet toward your side, remove the three
pawls from the rear side of the front cabinet.
4. Remove the glass holders (right and left) and remove
the document glass.
Remove the right and left glass holders and remove the document
glass.
5. Attach the front cabinet.
Attach the front cabinet of the copier.
At this time, ensure that the three pawls on the rear side are securely
inserted to the frame of the copier.
6. Attach the RSPF glass holder.
Insert the SPF glass holder to the document glass.
Then, attach the document glass to the copier, fix the left glass holder
that has been removed in step 3 using two screws (M3 x 8), and fix
the SPF glass using three screws (M3 x 8).
SPF glass cover
Screws (M3 x 8)
Screws (M3 x 8)
Pawls
Document glass
Right glass holder
Left glass holder
Pawls
Screws (M3 x 8)
Screws (M3 x 8)
Document glass
SPF glass holder