Read Sharp AR-SP2 (serv.man29) Technical Bulletin online
DCE060
Sharp Electronics (UK) Ltd., Technical Services Group
Date:
15 October 1999
Model: ARSP2
Ref.:
Ref.:
001
Colour: White
Page:
Page:
1 of 2
TECHNICAL BULLETIN
1. Countermeasure against folded original detection error when using the SPF.
1. Model Name:
ARSP2
2. General:
When copying folded originals with the SPF, the detection error of original detection
actuator may occur. Therefore, the original detection actuator has been changed to
enlarge the detection range.
actuator may occur. Therefore, the original detection actuator has been changed to
enlarge the detection range.
3. Description:
Parts name
Before change
After change
Original detect lever ACT
MLEVP0035QSZZ
MLEVP0035QSZ1
4. Action:
From July 1999 production.
2. Change of separator tray sheet.
1. Model name:
ARTR2
2. General:
Since the job separator is subject to the load of separator tray sheet, the separator tray
sheet has been made narrower to reduce the load.
sheet has been made narrower to reduce the load.
3. Description:
Parts name
Before change
After change
Thickness
Separator tray sheet
PSHEZ0159QSZZ
PSHEZ0159QSZ1
T = 0.25 0.1mm
4. Action:
From June 1999 production.
1.
COUNTERMEASURE AGAINST FOLDED ORIGINAL
DETECTION ERROR WHEN USING THE SPF.
DETECTION ERROR WHEN USING THE SPF.
2.
CHANGE OF SEPARATOR TRAY SHEET
.
DCE060
Sharp Electronics (UK) Ltd., Technical Services Group
Current Parts
New Parts
Ref
No.
Model
name
Version
P/G
No.
Parts code
Parts code
Price
rank
Parts name
Effec-
tive
time
Interc-
hange-
ability
Note
[34] –9
1
ARSP2
[1] –9
MLEVP0035QSZZ
MLEVP0035QSZ1
AD
Original detect lever
‘99/7
3
2
ARTR2
All
[1] -
PSHEZ0159QSZZ
PSHEZ0159QSZ1
AC
Separator tray sheet
‘99/6
3
<Interchange>
1. Interchangeable.
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of related parts in used.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
New type can be used in place of current type.
6. Others.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the
safety and performance of the set.
safety and performance of the set.
Display