AR-RP8. Service manual - Sharp Copying Equipment Service Manual (repair manual). Page 23

Read Sharp AR-RP8 Service Manual online

AR-SP8/RP8  TEST COMMAND  6 - 4
26
04
Main unit duplex setting 
(DPLX)
[Function]
When this test command is executed, the current set duplex is displayed. Enter the code number cor-
responding to the desired duplex and press [OK/START] key to save the setting. 
[Operation]
The operation is similar to test command 21-01.
41
06
OC cover float detection 
level (OC FLOAT LEVEL)
[Function]
When this test command is executed, the current set value is displayed. When [OK/START] key is
pressed, the mirror base unit moves to the SPF scan position to acquire the OC cover float detection
level.
When the mirror base unit returns to the home position, the acquired value is displayed.
If the detection level is not acquired, ERR display is made. (Default: 0)
Note that, this test command must be executed with the OC cover closed.
If the value is 0, float detection is not performed in normal jobs.
[Operation]
43
05
Fusing temperature setting 
in duplex copy (FU TEMP 
DPLX) (Enabled when 
Duplex setting is ON)
[Function]
In the case of duplex copy, the shift temperature set with this test command is applied to the fusing
temperature.
When this test command is executed, the current set code number is displayed. 
Enter the desired code number and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
46
20
SPF exposure correction 
(EXP.LEVEL SPF)
[Function]
Used to adjust the exposure correction amount in the SPF mode. The adjustment is made by adjust-
ing Vref voltage variation for the OC mode. 
When this test command is executed, the current set value is displayed in 2 digits (Default: 50).
Change the set value and press [START] key to save the setting and make a copy. 
When the set value is increased, copy becomes darker. When the set value is decreased, copy
becomes lighter. (Adjustment range: 1 – 99)
[Operation]
The operation is similar to test command 46-01.
Main 
code
Sub 
code
Contents
Details of function/operation
Code number
Duplex
Display item
0
Duplex NO
OFF
1
Duplex YES
ON
1) Initial display
2) [OK/START]
41-06 OC FLOAT LEVEL
               0    
41-06 OC FLOAT LEVEL
EXECUTING...
<Canceling - when C/CA key is pressed->
After canceling, the machine goes into the sub code entry
standby mode.
3) When the level is acquired:
3) When the level is not acquired:
THE JOB IS BEING
CANCELED.
41-06 OC FLOAT LEVEL
             **** OK 
41-06 OC FLOAT LEVEL
             **** ERR
Code
Shift temperature (°C)
Remark
0
±0
Default
1
-8
2
-6
3
-4
4
-2
5
±0
6
+2
7
+4
8
+6
9
+8
Mode
Display item
Default
Remark
SPF
SPF
50
Page of 26
Display

Click on the first or last page to see other AR-RP8 service manuals if exist.