AR-RP7 (serv.man2). Service manual - Sharp Copying Equipment Service Manual (repair manual). Page 3

Read Sharp AR-RP7 (serv.man2) Service Manual online

AR-RP7
UNPACKING AND INSTALLATION
– 2 –
2. Remove the glass holders (right and left) and remove
the document glass.
Remove the right and left glass holders and remove the document
glass.
Remove the two screws (M3x8) of the left glass holder and the three
screws (M3x8) of the right glass holder.
3. Attach the RSPF glass holder.
Insert the RSPF glass holder to the document glass.
Then, attach the document glass to the copier, fix the left glass holder
that has been removed in step 3 using two screws (M3x8), and fix the
RSPF glass using three screws (M3x8).
4. Attach the RSPF.
Insert the hinge portion of the RSPF to the mounting portion of the
copier by holding the RSPF at an angle toward the rear side.
5. Remove the filament tape.
Remove the filament tape located in the positions shown in the illustra-
tion.
6. Connect the relay connector.
Connect the Centronics connector of the RSPF to the connector of the
copier and then tighten the screws of the connector.
7. Attach the intermediate tray. 
Insert the intermediate tray all the way into the RSPF.
Screws (M3x8)
Screws (M3x8)
Left glass 
holder
Document glass
Right glass holder
Screws (M3x8)
Screws (M3x8)
Left glass 
holder
Document glass
RSPF glass holder
Hinge
Hinge
Filament tape
Filament tape
Filament tape
Screw
Screw
Intermediate tray
Page of 22
Display

Click on the first or last page to see other AR-RP7 (serv.man2) service manuals if exist.