14) Remove the left side cabinet.
15) Remove the cabinet angle. This angle is unnecessary when re-
moved. However, the screw which was fixing the angle is re-
quired to fix the printer I/F connector unit later.
16) Open the printer I/F connector window of the left rear cabinet.
(Cut the cabinet with nippers.)
17) Attach the printer I/F PWB with the accessory screw.
18) Use the screw noted in procedure 15) and attach the printer I/F
connector unit.
(NOTE)
When attaching the I/F connector mounting plate, be careful not to
apply an excessive stress to the connector which is passed under the
I/F connector mounting plate.
19) Use the flat cable to connect the printer I/F PWB and the printer
I/F unit. At that time, be careful of the connector direction. Also
check that the flat cable protector section (black section) passes
through the chassis edge. Bend the flat cable at the right angle
in two positions. Fix the flat cable with the cable clamp of the
printer I/F unit section and the flat cable clip.
20) Connect the wake up signal harness connector to the printer I/F
PWB, and connect the other end to the main harness wake up
signal connector.
21) Install all the parts that were removed to their original positions.
22) Connect the main unit and the printer controller with the printer
cable.
23) Attach the caution label to the cabinet. (Only EU version)
3. Setting
1) Turn on the power of the unit.
2) Enter the simulation 26-1 mode.
3) Press "PRN: AR-PE1" button. (Communication between the unit
and the printer controller is allowed.)
4) Cancel the simulation mode.