SHARP CORPORATION
S A F E T Y D A T A S H E E T
Page 1/2
1. Model : AR-M450
1.1 (electr.) Safety : Inspected acc;
1.1 (electr.) Safety : Inspected acc;
TUV(GS-MARK) SEMKO,NEMKO
1.2 Fire protection : acc. to NFPA ;
-
1.3 Radio Interference Suppression : inspected acc. ;
CE-Mark
1.4 Other tests : (e.g....) ;
-
1.5 Power consumption : Operation ; 1350 W (MAX. with option)
Low power mode ; 131.2 Wh(>223.25Wh)
Sleep /Off mode; 41.7 Wh(>95Wh)
Low power mode ; 131.2 Wh(>223.25Wh)
Sleep /Off mode; 41.7 Wh(>95Wh)
2. Emission
Measurement procedure : According to Blue Angel (25 , 50%RH)
Measurement conditions : room volume ; 50 m
Measurement procedure : According to Blue Angel (25 , 50%RH)
Measurement conditions : room volume ; 50 m
3
air exchange ; None per hour
test copy volume ; None no. of copies
testing time ; 2 hours
2.1 Heat (released) : Operation ; 4860 kJ = 4606.2 BTU
Low power mode ; 472.32 kJ = 447.6544 BTU
Sleep /Off mode; 150.12 kJ = 142.2804 BTU
(36x10
test copy volume ; None no. of copies
testing time ; 2 hours
2.1 Heat (released) : Operation ; 4860 kJ = 4606.2 BTU
Low power mode ; 472.32 kJ = 447.6544 BTU
Sleep /Off mode; 150.12 kJ = 142.2804 BTU
(36x10
5
J = 1 kwh = 3412 BTU )
2.2 Ozone concentration : 0.01165 mg/m
3
< 0.02mg/m
3
(RAL-UZ62 Supplement 2)
2.3 Dust concentration : 0.035 mg/m
3
< 0.075mg/m
3
(RAL-UZ62 Supplement 1)
Styrene-emission : 0.020 mg/m
3
< 0.07mg/m
3
(RAL-UZ62 Supplement 3)
2.4 UV-radiation : None
2.5 Noise emission (max.)
2.5.1 Sound power level : standby ; 4.6 B(A)< 5.0B(A) (EN27779)
operation ; 6.75(FAST) B(A) < 7.0B(A) (Nordic Swan)
6.8 (IMPULSE) B(A) <7.0B(A) (Blue Angel)
2.5.2 Workplace related
Sound pressure level: standby ; 32 dB(A) < 35dB(A) (EN27779)
Operation ; 50 dB(A) < 52dB(A) (EN27779)
2.6 NO : No data ppm < 5.0 ppm
2.5.1 Sound power level : standby ; 4.6 B(A)< 5.0B(A) (EN27779)
operation ; 6.75(FAST) B(A) < 7.0B(A) (Nordic Swan)
6.8 (IMPULSE) B(A) <7.0B(A) (Blue Angel)
2.5.2 Workplace related
Sound pressure level: standby ; 32 dB(A) < 35dB(A) (EN27779)
Operation ; 50 dB(A) < 52dB(A) (EN27779)
2.6 NO : No data ppm < 5.0 ppm
CO : No data ppm < 30.0 ppm
3. Max. air flow : No data m
3
/min.
4. Set up conditions
4.1 Minimum set up space: L(D); 552 W; 428 H; 469 mm
4.2 Air circulation: Not specified e.g. 0.5/h
4.3 Average monthly copy volume: 1200 (MAX 2000)
4.4 Room climate: humidity ; 20 % min. 80 % max.
temperature ; 15 min. 30 max.
4.1 Minimum set up space: L(D); 552 W; 428 H; 469 mm
4.2 Air circulation: Not specified e.g. 0.5/h
4.3 Average monthly copy volume: 1200 (MAX 2000)
4.4 Room climate: humidity ; 20 % min. 80 % max.
temperature ; 15 min. 30 max.
2001/July