AR-M700 (serv.man20). Details of each section - 5 Scanner section - Sharp Copying Equipment Service Manual (repair manual). Page 10

Read Sharp AR-M700 (serv.man20) Service Manual online

: Feb. 6 2004
1
AR-M550/M620/M700  DETAILS OF EACH SECTION  6 - 98
a-13. CCD lens unit 
1) Remove the table glass. (See “a-1. Table glass” in this section)
3) Mark the lens unit plate position by pen.
 
4) Release the connector lock on the CCD PWB to remove the FFC
cable.
5) Remove the screw to remove the CCD PWB lens unit.
6) Attach the CCD PWB lens unit to the marked position.
a-14. Scanner relay PWB
1) Remove the table glass. (See “a-1. Table glass” in this section)
2) Remove the harness cover B.
3) Disconnect the connector, and remove the scanner interface PWB.
a-15. Scanner motor
1) Remove the rear cabinet. 
2) Remove the spring and disconnect the connector.
2) Remove the harness clamp and the dark box.
1
1
1
1
Page of 12