AR-M700 (serv.man14). External view and internal structure - Sharp Copying Equipment Service Manual (repair manual). Page 9

Read Sharp AR-M700 (serv.man14) Service Manual online

: Feb. 9 2004
1
AR-M550/M620/M700  EXTERNAL VIEW AND INTERNAL STRUCTURE  5 - 9
M1SPD
M1SPD
Paper remaining quantity 
detector (Paper feed tray 3)
Paper remaining quantity 
detection (Paper feed tray 3)
Transmission 
type
-
Remaining 
paper quantity 
66% or less
PCU PWB
Paper feed tray 
remaining quantity 
sensor
M1SS1
M1SS1
Paper size detector (Paper feed 
tray 3)
Paper size detection by 
combination of ON/OFF of MISS1 
- 4
Tact switch
PCU PWB
Multi paper feed 
tray vertical size 
detection (Refer 
to the separate 
table in the “[14] 
SIGNAL NAME 
LIST” (*1).)
M1SS2
M1SS2
Paper size detector (Paper feed 
tray 3)
Paper size detection by 
combination of ON/OFF of MISS1 
- 4
Tact switch
PCU PWB
Multi paper feed 
tray vertical size 
detection (Refer 
to the separate 
table in the “[14] 
SIGNAL NAME 
LIST” (*1).)
M1SS3
M1SS3
Paper size detector (Paper 
feed tray 3)
Paper size detection by 
combination of ON/OFF of MISS1 
- 4
Tact switch
PCU PWB
Multi paper feed 
tray vertical size 
detection (Refer 
to the separate 
table in the “[14] 
SIGNAL NAME 
LIST” (*1).)
M1SS4
M1SS4
Paper size detector (Paper 
feed tray 3)
Paper size detection by 
combination of ON/OFF of MISS1 
- 4
Tact switch
PCU PWB
Multi paper feed 
tray vertical size 
detection (Refer 
to the separate 
table in the “[14] 
SIGNAL NAME 
LIST” (*1).)
M2SPD
M2SPD
Paper remaining quantity 
detector (Paper feed tray 4)
Paper remaining quantity 
detection (Paper feed tray 4)
Transmission 
type
-
Remaining 
paper quantity 
66% or less
PCU PWB
Paper feed tray 
remaining quantity 
sensor
M2SS1
M2SS1
Paper size detector (Paper feed 
tray 4)
Paper size detection by 
combination of ON/OFF of MISS1 
- 4
Tact switch
PCU PWB
Multi paper feed 
tray vertical size 
detection (Refer 
to the separate 
table in the “[14] 
SIGNAL NAME 
LIST” (*1).)
M2SS2
M2SS2
Paper size detector (Paper 
feed tray 4)
Paper size detection by 
combination of ON/OFF of MISS1 
- 4
Tact switch
PCU PWB
Multi paper feed 
tray vertical size 
detection (Refer 
to the separate 
table in the “[14] 
SIGNAL NAME 
LIST”  (*1).)
M2SS3
M2SS3
Paper size detector (Paper feed 
tray 4)
Paper size detection by 
combination of ON/OFF of MISS1 
- 4
Tact switch
PCU PWB
Multi paper feed 
tray vertical size 
detection (Refer 
to the separate 
table in the “[14] 
SIGNAL NAME 
LIST” (*1).)
M2SS4
M2SS4
Paper size detector (Paper feed 
tray 4)
Paper size detection by 
combination of ON/OFF of MISS1 
- 4
Tact switch
PCU PWB
Multi paper feed 
tray vertical size 
detection (Refer 
to the separate 
table in the “[14] 
SIGNAL NAME 
LIST” (*1).)
MHPS
MHPS
Scanner home position sensor
Scanner home position detection
Transmission 
type
Home position
PCU PWB
Sensor
OCSW
OCSW
SPF open/close detector
Document size detection trigger
Transmission 
type
Close
SCN PWB
Sensor
PCS
PCS
Image density sensor
Detection of density of toner patch 
on the OPC drum
Reflection type
-
-
PCU PWB
Analog detector
PDSELX
PDSELX
Document size sensor (Light 
reception) (PT)
Document size detection 
Photo 
transistor
-
-
SCN PWB
Other detector
RTH1
RTH1
Heat roller temperature sensor 
(Center section)
Heat roller temperature detection 
(Center section)
Thermistor
-
-
PCU PWB
Analog detector
RTH2
RTH2
Heat roller temperature sensor 
(Edge section)
Heat roller temperature detection 
(Edge section)
Thermistor
-
-
PCU PWB
Analog detector
RTH3
RTH3
Sub heat roller temperature 
sensor
Sub heat roller temperature 
detection
Thermistor
-
-
PCU PWB
Analog detector
SCOV
SCOV
SPF cover switch
SPF cover open/close detection
Transmission 
type
Close
SCN PWB
Sensor
Code
Signal 
name
Name
Function/Operation
Type
Connector level
PWB name
Note
"L"
"H"
1
1
1
1
1
1
1
1
1
1
Page of 24