AR-M620 (serv.man20). (9) Self diag message and troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 12

Read Sharp AR-M620 (serv.man20) Service Manual online

AR-M550/M620  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 12
Main 
code
Sub 
code
Title
CCD shading trouble (White 
correction all pixel adjustment)
E7
11
Phenomenon
Display
Lamp
Message
Details
Shading trouble (White 
correction all pixel 
adjustment)
The CCD white reference 
plate scan level 
abnormality when lighting 
the copy lamp
When the proper gain 
setup value is not 
obtained at turning on the 
power or CCD shading 
with SIM 63-2.
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Mirror, lens, reference 
white plate dirt
Remedy
Clean the mirror, the lens, 
and the reference white 
plate.
Note 
Case 2
Trouble 
position/
Cause
Copy lamp  lighting 
abnormality
Remedy
Check the light quantity 
and lighting of the copy 
lamp. (SIM 5-3)
Note 
Case 3
Trouble 
position/
Cause
Defective installation of 
the flat cable to the CCD 
unit
Improper installation of 
the CCD unit
CCD unit abnormality
Remedy
CCD unit check
Note 
Case 4
Trouble 
position/
Cause
Scanner PWB 
abnormality
Remedy
Scanner PWB check
Note 
Main 
code
Sub 
code
Title
CCD shading trouble (White 
correction center adjustment)
E7
12
Phenomenon
Display
Lamp
Message
Details
Shading trouble (White 
correction center 
adjustment)
The CCD white reference 
plate scan level 
abnormality when lighting 
the copy lamp
When the proper gain 
setup value is not 
obtained at turning on the 
power or CCD shading 
with SIM 63-2.
Section
Scanner
Operation 
mode
Note 
E7
12
Case 1
Trouble 
position/
Cause
Mirror, lens, reference 
white plate dirt
Remedy
Clean the mirror, the lens, 
and the reference white 
plate.
Note 
Case 2
Trouble 
position/
Cause
Copy lamp  lighting 
abnormality
Remedy
Check the light quantity 
and lighting of the copy 
lamp. (SIM 5-3)
Note 
Case 3
Trouble 
position/
Cause
Defective installation of 
the flat cable to the CCD 
unit
Improper installation of 
the CCD unit
CCD unit abnormality
Remedy
CCD unit check
Note 
Case 4
Trouble 
position/
Cause
Scanner PWB 
abnormality
Remedy
Scanner PWB check
Note 
Main 
code
Sub 
code
Title
CCD communication trouble
E7
14
Phenomenon
Display
Lamp
Message
Details
CCD communication 
trouble
Communication trouble 
between the scanner 
PWB and the CCD-ASIC. 
(Clock synchronization)
When an error occurs in 
the access check to the 
CCD-ASIC executed at 
turning on the power.
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Defective installation of 
the harness connected to 
the CCD unit
Remedy
Check the harness 
connected to the CCD 
unit.
Note 
Case 2
Trouble 
position/
Cause
CCD unit abnormality
Remedy
CCD unit check
Note 
Case 3
Trouble 
position/
Cause
Scanner PWB 
abnormality
Remedy
Scanner PWB check
Note 
Main 
code
Sub 
code
Title
CCD shading trouble (White 
correction center adjustment)
Page of 47
Display