Read Sharp AR-M620 (serv.man19) Service Manual online
AR-M550/M620 SIMULATION 8 - 76
Operation/Procedure
1) Enter the number corresponding to the set item with 10-key.
2) Press [START] key.
3) Enter the set value with 10key.
4) Press [START] key.
Operation/Procedure
1) Select 2 with 10-key.
2) Press [START] key.
3) Enter the adjustment value with 10key. (1 count: 0.1mm)
4) Press [START] key.
Operation/Procedure
This simulation is used to change and check the engine soft SW. Set
this setting to the default.
this setting to the default.
There is no need to change this setting in the market.
Select 4, and press [START] key.
Press [CUSTOM SETTINGS]
key.
key.
53-7
Purpose
Adjustment/Setup/Operation data output/Check
(Display/Print)
(Display/Print)
Function
(Purpose)
(Purpose)
Used to enter the SPF width detection adjustment
value.
value.
Section
DSPF
Item
Operation
Item
Set range
Default
1
MAX. POSITION
Max. width
0 - 1023
66
2
POSITION 1
Adjustment position 1
456
3
POSITION 2
Adjustment position 2
713
4
MIN. POSITION
Min. width
791
Press [START] key.
Press [CUSTOM SETTINGS] key.
1
Select 2, and press [START] key.
Select 3, and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1.MAX.POSITION
2.POSITION 1
3.POSITION 2
4.MIN.POSITION
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX.POSITION ... COMPLETE (or “ERROR”)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or “ERROR”)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or “ERROR”)
Select 1, and
press [START] key.
press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN.POSITION ... COMPLETE (or “ERROR”)
1
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). SELECT 1-4, AND PRESS
START.
1.MAX.POSITION:
66
2.POSITION 1 :
456
3.POSITION 2 :
713
4.MIN.POSITION:
791
66
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). INPUT VALUE 0-1023, AND
PRESS START.
1.MAX.POSITION
53-8
Purpose
Adjustment
Function
(Purpose)
(Purpose)
Used to adjust the document scan start position. (Used
to adjust the scanner scan position in the SPF mode
front scan.)
to adjust the scanner scan position in the SPF mode
front scan.)
Section
Item
Item
Item
Set
range
Default
2
MANUAL
Manual feed adjustment (Direct
entry of a number)
entry of a number)
1 - 60
32
Select 2, and
press [START] key.
press [START] key.
Press [START] key, or
press [CUSTOM SETTINGS] key.
press [CUSTOM SETTINGS] key.
55
55-1
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to set the specifications of the engine control
operations. (PCU PWB)
operations. (PCU PWB)
Section
Item
Item
Operation Specifications
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT. PRESS START.
2.MANUAL
25
25
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT. INPUT VALUE 1-35, AND
PRESS START.
2.MANUAL
1
SIMULATION 55-1
ENGINNE SOFT SW. SETTING. SELECT 1-16, AND PRESS START.
1 2 3 4 5 6 7 8
0 0 0 0 1 0 0 1
SIMULATION 55-1
ENGINNE SOFT SW. SETTING. INPUT DATA No(1-8), AND PRESS
START.
SOFT SW-1: