Read Sharp AR-M620 (serv.man18) Service Manual online
AR-M550/M620 SETTING AND ADJUSTMENTS 7 - 21
6) Select the number that corresponds to the adjustment item SPF
(SUB) using the numeric keypad.
This adjustment items is intended to adjust the image magnifica-
tion in the sub-scanning direction in SPF mode.
tion in the sub-scanning direction in SPF mode.
7) Press the Start key
8) Adjust the image magnification factor by entering an appropriate
value through the numeric keypad.
9) Press the P or Start key
Pressing the Start key starts copy operation as well as applying the
adjustment value.
adjustment value.
Repeat the above adjustments until an acceptable result is obtained.
Note: After adjusting the image magnification in the sub-scanning
direction through Simulation 48-1, do the following steps if mak-
ing a copy at a different magnification factor fails to produce a
correctly scaled copy.
ing a copy at a different magnification factor fails to produce a
correctly scaled copy.
1) Go through the modes specified in Simulation 48-5.
2) Using the numeric keypad, select the number that corresponds to
the mode for which to make adjustments.
2) Press the Start key
3) Enter the copy adjustment value using the numeric keypad.
Make adjustments by changing the adjustment value for high revo-
lution mode if the copy magnification is not correct for microcopies;
or the adjustment value for low revolution mode if the copy magnifi-
cation is not correct for blowbacks.
lution mode if the copy magnification is not correct for microcopies;
or the adjustment value for low revolution mode if the copy magnifi-
cation is not correct for blowbacks.
4) Press the Start key
This applies the adjustment value.
This adjustment is needed in the following situations:
• The paper feed section has been disassembled.
• The MFP control PWB has been replaced.
• The EEPROM on the MFP control PWB has been replaced.
• The scan control PWB has been replaced.
• The EEPROM on the scan control PWB has been replaced.
• The scanner (reading) section has been disassembled.
• The scanner (reading) unit has been replaced.
• The LSU has been replaced.
• U2 trouble has occurred.
(Print image off-center adjustment)
1) Go through the modes specified in Simulation 50-5.
Select 2, and
press [START] key.
press [START] key.
Press [START] key, or
press [CUSTOM SETTINGS] key.
press [CUSTOM SETTINGS] key.
50
1
2
Select other than 0 - 2,
and press [START] key.
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key,
or terminate copying.
or terminate copying.
Press [START] key, or
press [CUSTOM SETTINGS] key.
press [CUSTOM SETTINGS] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-9, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.MAGNIFICATION
100
3.CCD(MAIN)
50
4.CCD(SUB)
50
5.SPF(SUB)
50
6.CIS(MAIN)
50
7.SPF(MAIN)
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT 6.LCC
(ABOVE+10: DUPLEX MODE)
Select 1, and
press [START] key.
press [START] key.
Select 0, and press [START] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)
Select 0 - 5, and
press [START] key.
press [START] key.
Press [START] key, or press
[CUSTOM SETTINGS] key.
[CUSTOM SETTINGS] key.
ADJ 7
Adjusting the image off-center
ADJ 7A
Adjust the print image off-center (print
engine section)
engine section)
0
SIMULATION 48-5
MOTOR SPEED ADJUSTMENT. SELECT 0-4, AND PRESS START.
0.MIR(220)
50
1.MIR(110)
50
2.SPF(360)
50
3.SPF(220)
50
4.SPF(110)
50
50
SIMULATION 48-5
SCAN MOTOR SPEED ADJUSTMENT. INPUT VALUE 0-99, AND
PRESS START.
0.MIR(220)
Click on the first or last page to see other AR-M620 (serv.man18) service manuals if exist.