Read Sharp AR-M620 (serv.man110) Technical Bulletin online
Sharp Electronics (UK) Ltd., Document Systems Support
(7) Secure the relay connector (previously removed) harness through the wire hooks on the inside of the
saddle ejection frame (2 hooks) and with the securing rib.
(8) Pull the ejection sensor harness that is coming through the hole and connect it with the relay
connector.
(9) Bundle the sensor harness that was removed from the ejection tray and secure with bundle fastener
[2] and bundle fastener [3].
At this time, if the photo sensor becomes shielded from light, it will malfunction. Be sure to leave
about 30 mm from the harness bundle.
At this time, if the photo sensor becomes shielded from light, it will malfunction. Be sure to leave
about 30 mm from the harness bundle.
Click on the first or last page to see other AR-M620 (serv.man110) service manuals if exist.