AR-M550 (serv.man97). Improvement of the fusing unit. - Sharp Copying Equipment Technical Bulletin (repair manual). Page 3

Read Sharp AR-M550 (serv.man97) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
ARE798
Attaching the oil roller
1.  Tighten the pressure screws to release pressure
2.  Remove the two screws (F/R) of the unit, open the unit and remove the lower roller, (take care when removing
the lower roller not to damage it).
3.
Attach the CL roller bearings (x2) to the oil roller.
4.
Attach the oil roller to the CL roller SP parts of the pressure lever F/R.
5. 
Place the pressure roller, close the upper and lower units and tighten the screws F/R.
6. 
Loosen the pressure release screw to apply pressure.