Read Sharp AR-M550 (serv.man4) Service Manual online
: Feb. 6 2004
1
AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 59
a-20. Duplex cover open/close detector
1) Pull out the left door.
2) Open the door, and remove the cover.
3) Remove the duplex cover open/close detector.
a-21. Fusing discharge brush
1) Pull out the left door.
2) Remove the fusing discharge brush.
∗
Attach the fusing discharge brush so that it is fit with the rear end.
1
a-22. Reversing discharge brush
1) Pull out the left door.
2) Remove the switchback gate.
3) Remove the reversing discharge bursh.
∗
Attach the reverse discharge brush so that it is fit with the rib inside
and the parting line.
and the parting line.
1
Click on the first or last page to see other AR-M550 (serv.man4) service manuals if exist.