AR-M550/M620  ROM VERSION-UP METHOD  10 - 5
5. Turning OFF the power during the 
version-up procedure
If the power is turned OFF during the version-up procedure, normal
writing of data cannot be assured even though the machine can be
booted again.
In such a case, use the spare PCU PWB ROM, the MFP control PWB
ROM (boot, program), and the scanner control PWB ROM each of
which includes the program to be operated, and perform the version-
up procedure again.
Replace with the spare PCU, the controller boot, the scanner control
PWB ROM, and perform procedure “4.” for the replaced ROM again to
write data into it.
6. Version-up procedure flowchart
Update completed
 
Setting mistake? (6.)
 
NO 
NO  
YES 
 
YES
YES
 
YES
NO
 
NO
 
Set again.
Write the on-board 
files collectively. (4.)
NG is BOOT?
NG is SCAN FAX?
Result: OK?
YES
 
NO
YES
NO
YES
NO
Remove the BOOT Flash ROM and 
replace it with a spare one. (If there is 
any NG Flash ROM, replace it, too.)
Booted normally?
Write the on-board files 
collectively. (4.)
Result: OK?
Result: OK?
Update completed
Update completed
Write with an empty 
socket. (5.)
If the Flash ROM itself is 
defective, replace it with a 
new one and try again.