AR-M550 (serv.man17). (10) ROM version-up method - Sharp Copying Equipment Service Manual (repair manual). Page 2

Read Sharp AR-M550 (serv.man17) Service Manual online

AR-M550/M620  ROM VERSION-UP METHOD  10 - 2
2. Precautions
A. Relationship between each ROM and version-up
When performing ROM version-up, be sure to check the combination
with the version of ROM installed in the other PWB's including optional
ones.
Some combinations of ROM versions may not operate the machine
properly.
3. Necessary items for Flash ROM version-
up
A machine with ROM to be operated
A spare PCU PWB ROM, an MFP control PWB ROM (Boot, Pro-
gram), a scanner control PWB ROM (Each of which is provided with
the program to allow operations.) (Used when writing the program
files into the ROM is failed.)
A PC operating on MS-DOS, with either of a USB, Ethernet, or paral-
lel port.
USB cable, Ethernet cable, or parallel I/F cable (for connection of PC
and MFP control PWB)
FCOPY.EXE file (Parallel I/F, file transfer tool)
File2PRN.exe file (A file transfer tool for parallel, Ethernet, and USB
protocols)
Version-up program (compression) file
(The SFU file for writing a program to each ROM of the PCU PWB, the
MFP control PWB (boot, program), and the scanner control PWB, or
the SFU file for writing all the programs collectively.)
4. Flash ROM version-up method
A. MFP control PWB ROM DIP switch selection and 
Flash ROM slot
To make version-up of the ROM, the DIP set on the MFP control PWB
on the side of the machine must be properly selected.
When writing the program into each ROM (PCU, FAX, and scanner
control PWB ROM) of each PWB individually by using an empty slot
for ROM copy on the MFP control PWB ROM, the protect switch and
the diag mode switch of the MFP control PWB ROM are switched
over.
(MFP control PWB ROM slot)
The MFP control PWB ROM is provided with three Flash ROM slots:
CN4, CN5, and CN6.
The boot ROM is installed to CN4, and the main ROM is installed to
CN5. CN6 is an empty slot.
Us this empty slot of the MFP control PWB, CN6, to copy the ROM pro-
gram.
When writing the program files collectively without disassembling the
ROM's from the PWB's, and when writing the program files into an
optional ROM:
The protect switch and the diag mode switch of the target PWB ROM
of writing program files are switched.
B. Operation panel
B. Operation panel
When entering the diag mode to write into ROM, some keys on the
operation panel and the LED panel are used. Necessary information
including menu items and messages is displayed on the LCD panel.
[START] key is used as [OK] key, [DOCUMENT FILING] key and
[FAX/IMAGE SEND] key as up/down select keys, [JOB STATUS] key
as [MENU] key, and [CLEAR] key as [BACK] key.
(NOTE)
1) When performing version-up of the firmware by using the tile trans-
fer tool (File1PRN), the printer driver of the target model must be
installed in advance. 
2) When performing version-up of the firmware by using the USB I/F,
take note of the following items.
Since the port for the file transfer tool (File2PRN) differs from the
port for the print mode, if the port for the print mode has been
already made, be careful not to mistake them. If the USB port for
the print mode has been made, it is advisable to delete it in order to
avoid confusion. 
(Making procedures of the port for the file transfer tool (File2PRN) in
the USB I/F mode)
When performing version-up of the firmware by using the USB I/F, per-
form the following procedures to make the port in advance.
1) Install the printer driver of the target model. 
In this case, set the port to other than the USB mode. 
2) Set the DIP switch to the Flash ROM version-up mode, and turn on
the power. 
3) Connect the PC and the main unit with a USB cable. 
4) The PC detects the new hardware by Plug & Play function. 
5) The driver of SHARP AR-M620N is automatically installed. (The
model name is indicated as SHARP AR-M620N, regardless of the
actual model name.)
Front frame side
Rear frame side
Switch
Diag mode
Controller write protect
PCU write protect
Scanner write protect
FAX write protect
Enlarged view of DIP switch
Controller PWB
Normal mode
Diag mode/
Write protect 
cancel mode
DIP switch
LCD panel
Up/Down key
BACK key
OK key
MENU key
Page of 6
Display