AR-M550 (serv.man16). (9) Self diag message and troubleshooting - Sharp Copying Equipment Service Manual (repair manual). Page 38

Read Sharp AR-M550 (serv.man16) Service Manual online

AR-M550/M620  SELF DIAG MESSAGE AND TROUBLESHOOTING  9 - 38
Main 
code
Sub 
code
Title
Memory check sum error (PCU)
U2
91
Phenomenon
Display
Lamp
Message
Details
Memory check sum error 
(PCU)
When POF data/counter 
data sum error is 
detected.
Section
Engine
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
EEPROM trouble
Remedy
Check that the EEPROM 
is properly installed.
In the simulation to 
prevent against delete of 
the counter data/
adjustment values, write 
down the counter/
adjustment values.
Note 
Case 2
Trouble 
position/
Cause
Control circuit runaway 
due to noises
Remedy
Use SIM 16 to cancel the 
U2 trouble.
Note 
Case 3
Trouble 
position/
Cause
PCU PWB EEPROM 
access circuit trouble
Remedy
Replace the PCU PWB.
Note 
Main 
code
Sub 
code
Title
SPF tray lift-up trouble
U5
30
Phenomenon
Display
Lamp
Message
Details
SPF tray lift-up trouble
Lift-up trouble is detected 
5 times continuously.
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
STUD/STLD trouble
STUD does not turn on 
within the specified time.
STLD does not turn off 
within the specified time.
Remedy
Check the harness and 
the connector of the 
STUD and STLD.
Lift-up trouble unit check
Note 
Main 
code
Sub 
code
Title
SPF tray lift-down trouble
U5
31
Phenomenon
Display
Lamp
Message
Details
SPF tray lift-down trouble
STLD does not turn off 
within the specified time.
Section
Scanner
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
STUD/STLD trouble
STUD does not turn on 
within the specified time.
STLD does not turn off 
within the specified time.
Remedy
Check the harness and 
the connector of the 
STUD and STLD.
Lift-up trouble unit check
Note 
Main 
code
Sub 
code
Title
LCC lift motor trouble
U6
09
Phenomenon
Display
Lamp
Message
Details
LCC lift motor trouble
• The upper limit sensor 
does not turn on within 
24 sec after the lift 
motor is on.
• No rotation sensor 
signal is detected for 
0.2 sec or longer while 
the lift motor is on.
• The upper limit switch 
is on while the lift motor 
is on.
When the trouble occurs 
3 time continuously that 
the upper limit sensor 
does not turn on.
Section
LCC
Operation 
mode
Note 
Case 1
Trouble 
position/
Cause
Sensor trouble
LCC control PWB trouble
Gear breakage
Lift motor trouble
Remedy
Use SIM to check the 
sensor detection.
Use SIM to check the lift 
motor operation.
Use SIM 15 to cancel the 
trouble.
Note 
Page of 47
Display